Recommended time interval for the maintenance of stainless body parts:
ATTENTION!
DO NOT WASH STAINLESS STEEL SHEETS
BY WATER OR EVEN SURFACTANT!!
Recommended procedure for stainless steel sheets:
Washing of parts by thorough cleaning of salt residues, dust
and grease followed by the renewal of protective coating on
body parts - by special agent for the protection of stainless
steel sheet - once a month.
Recommended special agents:
-
NEOBLANK spray (producer: Chemische Fabrik Dr. Weight
GmbH & Co. KG, Mühlenhagen 85 - D - Hamburg
-
ANTOX Surface Care 800 S (producer: Chemetall AG,
Silostrasse 7, CH - 5606, Dintikon
-
ULTRAPUR – d ( producer: MMM – Group, SRN)
9.10.
Electronic counter
No maintenance of the electronic counter is performed. Any manipulation with the counter and wiring
of the dispenser can be only performed by a qualified person.
The electronic counter itself is repaired by replacement at the filling station.
10.
DISASSEMBLY AND DISPOSAL
Considering the fact that the residues of fuel always are left in hydraulic distributing systems and in
hydraulic parts of the dispenser it is necessary to pay higher attention to the disassembly and disposal.
The dismantling must be carried out on dripping grids where the residues of fuels are safely
removed into dripping tanks.
It is forbidden to carry out the disposal by using burners and sparkling device.
Hoses have to be disposed according to special regulations for the disposal of ecologically undesirable
materials.
11.
SUMMARY OF BASIC PRINCIPLES FOR DISPENSER MAINTENANCE
ATTENTION!
Prior to all maintenance activities relevant to mechanical, hydraulic or electric parts it is always
necessary to switch el. current off and carry out reliable provision to prevent its incidental
switching on.
Service manipulation is performed in accordance with operating regulations for the filling station.
-
replace the filter sleeve of the pump filter in compliance with the mode of operation and ensure
proper reassembly of the filter
-
keep all operating units of dispenser clean to enable easy identification and rapid repair of
unexpected failure
-
check systematically all joints and if any leakage is identified, retighten the joint or make it
tight
-
check and tighten the V-belt by means of a swivelling bracket of the motor if required
-
check and if required tighten the bolts fixing the el. motor and the monoblock to the bracket
Содержание MINOR V-line 899 Series
Страница 2: ......
Страница 25: ...USER S MANUAL V line 899x xxx 21 Pic 6 Pic 7 ...
Страница 28: ...V line 899x xxx USER S MANUAL 24 Pic 15 Pic 16 ...
Страница 29: ...USER S MANUAL V line 899x xxx 25 Pic 10 Scheme of inputs and outlets of the unit VAPORIX Control ...
Страница 64: ......
Страница 69: ...USER S MANUAL V line 899x xxx Enclosure no 5 View of dispensers V line 899x 4x2 series ...
Страница 80: ...V line 899x xxx USER S MANUAL Enclosure no 16 V line dimensions of V line 899x 6x4 S P dispensers ...