The fault in the revelant system must be fixed by specialised service worker within a period of
7 days (168 hod).
4. VRC system works out of setled tolerance – permanent fault mode – after expire of 7-
days time period (168 hours)
In the event that the fault of system VRC is not fixed by spealised service worker within a
period of 7-days (168 hours) , the functionality of the fuel dispenser will be permanently
blocked (given delivery place of the fuel dispenser)!!
System status indication on the unit VRMS VAPORIX-Control:
In the event that the fault system VRC is a professional service person within a specified period of 7 days
(168 hours) removed - the unit VAPORIX Control (Pic. 9 – pos. 7/side A or pos. 8/side B)
„DIODE
FLASHING RED“ - „signal STOP“
– the vapor flow values are outside the specified tolerance.
System status indication VRMS on the fuel dispenser:
On the front cover (mask) the electronics housing
„DIODE FLASHING RED“ - „signal STOP“ – pos. 2:
Pic. 14
Notice:
Electrical connection of V-line 899x.xxx dispensers with vapour recovery system with automatic
control system
VRMS (Vapour Recovery Monitoring System) - see the enclosure no. 38.
Diesel oil filling points are not equipped with the vapour exhaust system.
Содержание MINOR V-line 899 Series
Страница 2: ......
Страница 25: ...USER S MANUAL V line 899x xxx 21 Pic 6 Pic 7 ...
Страница 28: ...V line 899x xxx USER S MANUAL 24 Pic 15 Pic 16 ...
Страница 29: ...USER S MANUAL V line 899x xxx 25 Pic 10 Scheme of inputs and outlets of the unit VAPORIX Control ...
Страница 64: ......
Страница 69: ...USER S MANUAL V line 899x xxx Enclosure no 5 View of dispensers V line 899x 4x2 series ...
Страница 80: ...V line 899x xxx USER S MANUAL Enclosure no 16 V line dimensions of V line 899x 6x4 S P dispensers ...