V-line 899x.xxx
USER’S MANUAL
30
5.5.
Signalling of dispenser conditions (SO)
On Client’s special requirement the fuel dispenser can be equipped with a red signal light, which gives
information to the customer and the operator about the present dispenser condition – the dispenser is
blocked or ready for fuel filling.
5.6.
SOPA design
On Client’s special request the dispenser in service mode can be equipped with magnetic release switch
(SOPA design). The operator of the filling station can release the dispenser for single filling operation in
this mode. After nozzle lifting the displays are reset and fuel filling is started. After hanging up the
nozzle, the dispensed volume and quantity values are permanently displayed until the dispenser is
magnetic released and the dispensing nozzle is lifted off subsequently. The red signal light informs both
the operator and the customer about the condition of the dispenser.
5.7.
Design with heating of the electronic case
On the special customer´s requirement the fuel dispenser can be delivered with heating of electronic
case by heater 250 VA. For feeding of the heating is used an individual cable - see the enclosure no. 37.
6.
TECHNICAL DATA
6.1.
Basic parameters for the classical and alternative fuels with dynamic viscosity up to 20 mPa.s
Electronic counter
ADP1/T, ADP2/T, ADP1/L
Tankautomat (CRID)
ADAMAT/PNN, ADAMAT/PNA
Display
Iluminated LCD - BACK LIGHT DISPLAY (BLD)
ADAMAT - Graphic BLD, Touch screen
Connecting flange of the suction piece – suction
system (899x.xxx/S)
DN 40 with inner thread G 1 1/2“ for
Q = 40, 2 x 40, 60, 70, 80, 110, 120,130, 150 dm
3
.min
-1
Connecting piece – pressure system (899x.xxx/P)
DN 40 with outer thread G 1 1/2“ for
Q = 40, 2 x 40, 60, 70, 80, 110, 120, 130, 150 dm
3
.min
-1
Required inner diameter of suction piping –
suction system (46xx)
DN 40 for flowrate Q = 40, 60 dm
3
.min
-1
DN 50 for flowrate Q = 2 x 40, 70, 80 dm
3
.min
-1
2 x DN 50 for flowrate Q = 110, 120, 130, 150 dm
3
.min
-1
Piping innner diameter required –
pressure system (47xx)
DN 40 for flowrate Q = 40, 2x 40, 60, 70, 80 dm
3
.min
-1
DN 50 for flowrate Q = 110, 120, 130, 150 dm
3
.min
-1
Max. flowrate Q
max
1)
40, 60, 70, 80, 110, 120, 130, 150 dm
3
.min
-1
Min. flowrate Q
min
1)
4, 5, 10, 15 dm
3
.min
-1
Operating flowrate Q 2)
40 - 150 dm
3
.min
-1
± 10 %
Accuracy of measurement
± 0,5 %
Max. operating pressure p
max
for Q
max
= 40 – 60 dm
3
.min
-1
0,25 MPa
for Q
max
= 70 – 150 dm
3
.min
-1
0,32 MPa
Min. operating pressure p
min
for Q
max
= 40 – 60 dm
3
.min
-1
0,12 MPa
for Q
max
= 70 – 150 dm
3
.min
-1
0,19 MPa
Ambient operating temperature
Standard -20 °C to +50 °C;
special -40 °C to +55 °C / -40 °C to +60 °C
Medium temperature
-20 °C to +50 °C for gasoline, diesel, E 10 to E 85; B 10 to B 60
-10 °C to +50 °C for B 70 to B 100, vegetable and mineral oils
Filtering property
30 µm for petrol
30 µm for Diesel oil (60 µm - for extreme temper. below -25 °C)
Reach of dispensing hose
4 to 6 m
Max. level of noise
<70 dB - 899x.xxx/S / <60 dB - 899x.xxx/P
El. motor power supply
3/PE AC 3x 230/400 V ±15 %, 50 Hz
Output of pump el. motor
P
3f
0,75 kW, 1,1 kW
Output of vacuum pump el. motor
P
3f
0,18 kW; 0,37 kW
Power supply of electronics
U
nap
P
nap
1/N/PE AC 230 V ±15 % 50 Hz
input 85 VA
Power supply of ADAMAT
U
nap
P
nap
1/N/PE AC 230 V ±15 % 50 Hz
input 120 VA
Power supply of electronic case
heating
U
nap
P
nap
1/N/PE AC 230 V ± 15 %, 50 Hz
input 250 VA
Содержание MINOR V-line 899 Series
Страница 2: ......
Страница 25: ...USER S MANUAL V line 899x xxx 21 Pic 6 Pic 7 ...
Страница 28: ...V line 899x xxx USER S MANUAL 24 Pic 15 Pic 16 ...
Страница 29: ...USER S MANUAL V line 899x xxx 25 Pic 10 Scheme of inputs and outlets of the unit VAPORIX Control ...
Страница 64: ......
Страница 69: ...USER S MANUAL V line 899x xxx Enclosure no 5 View of dispensers V line 899x 4x2 series ...
Страница 80: ...V line 899x xxx USER S MANUAL Enclosure no 16 V line dimensions of V line 899x 6x4 S P dispensers ...