background image

 

 

 

 

 
 

 
 

 

Manufacturer’s Declaration of Conformity 

 

This product has been manufactured in accordance with the harmonised European standards, 

following the provisions of the below stated directives: 

 

Electro Magnetic Compatibility Directive 89/336/EEC  

 

Low Voltage Directive 73/23/EEC  

 

Adam Equipment Co. Ltd. 

Bond Avenue, Denbigh East  

Milton Keynes, MK1 1SW 

United Kingdom 

 

FCC COMPLIANCE 

 

This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a commercial environment.  The 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own expense. 

 

Shielded interconnect cables must be employed with this equipment to insure compliance with the 
pertinent RF emission limits governing this device. 

 

Changes or modifications not expressly approved by Adam Equipment could void the user's 
authority to operate the equipment. 

 

WEEE COMPLIANCE 

 

 

Any Electrical or Electronic Equipment (EEE) component or assembly of parts intended to be 
incorporated into EEE devices as defined by European Directive 2002/95/EEC must be recycled or 
disposed using techniques that do not introduce hazardous substances

 harmful to our health or the 

environment as

 listed in Directive 2002/95/EC or amending legislation.  Battery disposal in Landfill 

Sites is more regulated since July 2002 by regulation 9 of the Landfill (England and Wales) 
Regulations 2002 and Hazardous Waste Regulations 2005. Battery recycling has become topical 
and the Waste Electrical and Electronic Equipment (WEEE) Regulations are set to impose targets 
for recycling. 

 

 

 

@Adam Equipment Company 2007

 

 

 

Содержание CFC SERIES

Страница 1: ...Adam Equipment CFC SERIES SERVICE MANUAL ADAM EQUIPMENT CO LTD P N 7952 Rev A2 February 2007 Adam Equipment Company 2007...

Страница 2: ...Adam Equipment Company 2007...

Страница 3: ...E 4 3 0 ERROR CODES 5 4 0 CFC DESCRIPTION 6 5 0 CFC USER PARAMETERS 7 6 0 CFC USER CALIBRATION 9 7 0 CFC FACTORY PARAMETERS AND CALIBRATION 10 7 1 FACTORY CALIBRATION 12 8 0 LOAD CELL DAMAGE 13 9 0 RE...

Страница 4: ...Adam Equipment Company 2007 2...

Страница 5: ...t telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soo...

Страница 6: ...through table Temperature changed dramatically Electronics faulty Battery low Weight value incorrect Calibration error Recalibrate Unit calibrated with inaccurate weight Balance not level Obstruction...

Страница 7: ...t on the pan when zeroing the scale Improper calibration of the scale Damaged load cell Damaged Electronics Err 5 Keyboard error Improper operation of the scale Err 6 A D count is not correct when tur...

Страница 8: ...d the most cost effective method of solving the problem is to replace the circuit board The main PCB assembly includes Sections for load cell input filter A D converter AU1 Microprocessor and support...

Страница 9: ...t any time press the Zero key to return to weighing Display Description F1 CAL See the calibration section for details F2 CAP Selects the scale capacity Scroll through the available options using the...

Страница 10: ...he weight only Press Tare to select and return to the sub menu PArity Select from the following settings n 8 1 8 data bits no parity E 7 1 7 data bits even parity o 7 1 7 data bits odd parity Press Ta...

Страница 11: ...lace the calibration weight on the scale and press the Tare key The scale will calibrate and then start the initial self check procedure counting from 9 to 0 Remove the weight during the counting CFCa...

Страница 12: ...ro key to return to weighing Display Description F1 CAL See the factory calibration section for details F2 CAP Selects the scale capacity Scroll through the available options using the M key Press Tar...

Страница 13: ...unit weight no of pieces and the total weight SEI rE Continuously print the weight only Press Tare to select and return to the sub menu PArity Select from the following settings n 8 1 8 data bits no p...

Страница 14: ...display will show LOAd Place the calibration weight on the scale and press the Tare key The scale will calibrate and then start the initial self check procedure counting from 9 to 0 Remove the weight...

Страница 15: ...auges to consider Normally without a load on the load cell all the resistances are the same However when the load cell has a weight on it 2 of the strain gauges will be in compression A and D and the...

Страница 16: ...OLT POWER SUPPLY Vout O VOLTS BETWEEN S AND s A method to check the basic function and integrity of a load cell can be done using an ohmmeter and voltmeter with up to a 10volt power supply Before the...

Страница 17: ...pacity with 20Kg placed on it Vext is 5 volts would give a output of approximately Vout 2mv V Vext Mass 2mv V 5V 20Kg 6 7mv capacity of load cell 30kg If the load cell has been damaged the no load vol...

Страница 18: ...of Load Cell 1 16 Load Cell 100kg 1 16 Load Cell 200kg 1 16 Load Cell 500kg 1 16 Load Cell 750kg 1 17 Pole 1 18 Bottom Bracket of Load Cell 1 19 Screw M6x8 3 20 Base to Pole Bracket 1 21 Base Washer...

Страница 19: ...Adam Equipment Company 2007 17...

Страница 20: ...n the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor...

Страница 21: ...y to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compl...

Страница 22: ...ns without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information...

Отзывы: