WARRANTY INFORMATION 

 

Adam Equipment offers one year Limited Warranty (Parts and Labour) for the 
components failed due to defects in materials or workmanship.  Warranty starts 
from the date of delivery. 
 
During the warranty period, should any repairs be necessary, the purchaser must 
inform its supplier or Adam Equipment Company. The company or its authorised 
Technician reserves the right to repair or replace the components at any of its 
workshops depending on the severity of the problems. However, any freight 
involved in sending the faulty units or parts to the service centre should be borne 
by the purchaser. 
 
The warranty will cease to operate if the equipment is not returned in the original 
packaging and with correct documentation for a claim to be processed. All claims 
are at the sole discretion of Adam Equipment. 
 
This warranty does not cover equipment where defects or poor performance is 
due to misuse, accidental damage, exposure to radioactive or corrosive materials, 
negligence, faulty installation, unauthorised modifications or attempted repair or 
failure to observe the requirements and recommendations as given in this User 
Manual. 
        
Repairs carried out under the warranty does not extend the warranty period. 
Components removed during the warranty repairs become the company property. 
        
The statutory right of the purchaser is not affected by this warranty. The terms of 
this warranty is governed by the UK law. For complete details on Warranty 
Information, see the terms and conditions of sale available on our web-site. 

@Adam Equipment Company 2007

 

 

 

18

Содержание CFC SERIES

Страница 1: ...Adam Equipment CFC SERIES SERVICE MANUAL ADAM EQUIPMENT CO LTD P N 7952 Rev A2 February 2007 Adam Equipment Company 2007...

Страница 2: ...Adam Equipment Company 2007...

Страница 3: ...E 4 3 0 ERROR CODES 5 4 0 CFC DESCRIPTION 6 5 0 CFC USER PARAMETERS 7 6 0 CFC USER CALIBRATION 9 7 0 CFC FACTORY PARAMETERS AND CALIBRATION 10 7 1 FACTORY CALIBRATION 12 8 0 LOAD CELL DAMAGE 13 9 0 RE...

Страница 4: ...Adam Equipment Company 2007 2...

Страница 5: ...t telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soo...

Страница 6: ...through table Temperature changed dramatically Electronics faulty Battery low Weight value incorrect Calibration error Recalibrate Unit calibrated with inaccurate weight Balance not level Obstruction...

Страница 7: ...t on the pan when zeroing the scale Improper calibration of the scale Damaged load cell Damaged Electronics Err 5 Keyboard error Improper operation of the scale Err 6 A D count is not correct when tur...

Страница 8: ...d the most cost effective method of solving the problem is to replace the circuit board The main PCB assembly includes Sections for load cell input filter A D converter AU1 Microprocessor and support...

Страница 9: ...t any time press the Zero key to return to weighing Display Description F1 CAL See the calibration section for details F2 CAP Selects the scale capacity Scroll through the available options using the...

Страница 10: ...he weight only Press Tare to select and return to the sub menu PArity Select from the following settings n 8 1 8 data bits no parity E 7 1 7 data bits even parity o 7 1 7 data bits odd parity Press Ta...

Страница 11: ...lace the calibration weight on the scale and press the Tare key The scale will calibrate and then start the initial self check procedure counting from 9 to 0 Remove the weight during the counting CFCa...

Страница 12: ...ro key to return to weighing Display Description F1 CAL See the factory calibration section for details F2 CAP Selects the scale capacity Scroll through the available options using the M key Press Tar...

Страница 13: ...unit weight no of pieces and the total weight SEI rE Continuously print the weight only Press Tare to select and return to the sub menu PArity Select from the following settings n 8 1 8 data bits no p...

Страница 14: ...display will show LOAd Place the calibration weight on the scale and press the Tare key The scale will calibrate and then start the initial self check procedure counting from 9 to 0 Remove the weight...

Страница 15: ...auges to consider Normally without a load on the load cell all the resistances are the same However when the load cell has a weight on it 2 of the strain gauges will be in compression A and D and the...

Страница 16: ...OLT POWER SUPPLY Vout O VOLTS BETWEEN S AND s A method to check the basic function and integrity of a load cell can be done using an ohmmeter and voltmeter with up to a 10volt power supply Before the...

Страница 17: ...pacity with 20Kg placed on it Vext is 5 volts would give a output of approximately Vout 2mv V Vext Mass 2mv V 5V 20Kg 6 7mv capacity of load cell 30kg If the load cell has been damaged the no load vol...

Страница 18: ...of Load Cell 1 16 Load Cell 100kg 1 16 Load Cell 200kg 1 16 Load Cell 500kg 1 16 Load Cell 750kg 1 17 Pole 1 18 Bottom Bracket of Load Cell 1 19 Screw M6x8 3 20 Base to Pole Bracket 1 21 Base Washer...

Страница 19: ...Adam Equipment Company 2007 17...

Страница 20: ...n the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor...

Страница 21: ...y to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compl...