AMW-Scoop Digital Scale
150g x 0.1g
USER’S MANUAL
ON/OFF
CAL
TARE
oz / g
g
Страница 1: ...AMW Scoop Digital Scale 150g x 0 1g USER S MANUAL ON OFF CAL TARE oz g g ...
Страница 2: ...least one hour before use Give your scale sufficient warm up time Usually 30 60 seconds before calibration to give the internal components a chance to stabilize Keep your scale in a clean environment Dust dirt moisture vibration air currents and a close proximity to other electronic devices can cause an adverse effect on the reliability and ac curacy of your scale Handle with care Gently apply all...
Страница 3: ...ARE and wait until 0 0 is displayed 4 Add the net weight item III Calibration 1 Turn on the scale and wait until display shows 0 0 2 Press and hold the CAL button for several seconds The display will show CAL then 0 0 3 Press the CAL button again and the display will show 100 0g 4 Now place a 100g calibration weight onto the weighing sur face Wait 5 seconds then press CAL again the display will sh...
Страница 4: ...ion instru ment and must be handled with care Error Code Descriptions Error Nothing on screen LO Solution Replace Batteries Error EEEE Solution Load is in excess of 150g remove the extra load IV Specifications Capacity 150 g 5 3 oz Readability 0 1 g 0 005 oz Units g grams oz ounces Tare Range Tare to full capacity Auto Off 30 seconds Backlight Blue backlight Power 1 x CR2032 Battery Scale Dimensio...