4.3.6. Connection to a C13 or C33 suction pipe
C13 type connection:
Air inlet and gas evacuation through concentric ducts connected to a
horizontal concentric terminal (suction pipe).
C33 type connection:
Air inlet and gas evacuation through concentric ducts connected to a vertical
concentric terminal.
WARNING:
The use of the “Horizontal suction pipe” accessory is mandatory to
connect the boiler to a C13 concentric suction pipe.
The use of the “Vertical black suction pipe” or “Vertical ochre suction
pipe” accessory is mandatory to connect the boiler to a C33 concentric
suction pipe.
Approved conduits are M&G Skyline conduits and terminals may also be
used.
Figure 9 - C13 type connection
Figure 10 - C33 type connection
A indicates the upper position of the
boiler gas outlet.
A min
L
A
L