ActronAir
is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice.
Copyright © 2017 Actron Engineering Pty. Ltd.
Page 11 of 36
UNIT PREPARATION
1. Remove mounting screws, as shown below:
2. Remove Access Panel.
• Remove Access Panel-Electrical as illustrated below:
3. Install Interconnecting Field Pipes
•
Solder refrigeration piping. Refer to piping sections for details of field pipe sizes and piping installation
procedure.
NOTE:
• There is an earth cable attached to the access panel.
This must be disconnected first to fully remove the access
panel.
• It is important to re-connect the earth cable when
re-assembling the access panel.
THIRD ANGLE
PROJECTION
Drawing Release
D
E
F
C
B
A
3
2
1
5
C
D
4
6
7
8
A
B
UNIT ASSY CRV2-14AS-0200
8011-682
7/06/2015
DL
See Notes
A3
SHEET 1 OF 1
N.T.S
DRAWING NO.
MATERIAL:
DESCRIPTION:
DATE
DRAWN BY:
APPROVED BY:
SCALE:
DRAWN DATE:
DESCRIPTION
FINISH:
REV
7/06/2015
N/A
PCR
P283
F
E
REV.
A
DL
ASS
EMBLY
8011-
682
BY
A.B.N. 34 002 767 240
PH. +61 2 8814 4000
Bella Vista NSW 2153
Norwest Business Park
5 Irvine Place
written consent is prohibited
See Notes
Modifying or Distributing without
Engineering Pty Ltd. Copying,
3.
intellectual property of Actron
This drawing always remains the
ActronAir Pty Ltd
FOLD
7.
3
1.
HOLE DIAMETER
0.5 / m
0.1/~0
2.
FLAT PATTERN
4.
ANGLES & SQUARENESS
0.5 / m
5.
1
GENERAL TOLERANCES
(UNLESS OTHERWISE SPECIFIED)
ALL TUBES
UNLESS OTHERWISE SPECIFIED
3rd ANGLE PROJECTION.
1.
DIMENSIONS IN MILLIMETRES.
2.
DO NOT SCALE.
3.
TUBE ENDS MUST BE ROUND AND OF FULL
4.
DIAMETER.
TUBE MUST BE CLEAN AND FREE FROM
5.
BURRS INSIDE AND OUTSIDE AND SUITABLE
OF FOR SOLDERING.
ALL BENDS 90 .
6.
ALL SHEETMETAL'S DIMENSIONS OUTISDE.
A
Access
Panel
Outdoor
Unit
Mounting
Screws
Mounting
Screws
THIRD ANGLE
PROJECTION
Drawing Release
D
E
F
C
B
A
3
2
1
5
C
D
4
6
7
8
A
B
UNIT ASSY CRV2-14AS-0200
8011-682
7/06/2015
DL
See Notes
A3
SHEET 1 OF 1
N.T.S
DRAWING NO.
MATERIAL:
DESCRIPTION:
DATE
DRAWN BY:
APPROVED BY:
SCALE:
DRAWN DATE:
DESCRIPTION
FINISH:
REV
7/06/2015
N/A
PCR
P283
F
E
REV.
A
DL
ASS
EMBLY
8011-
682
BY
A.B.N. 34 002 767 240
PH. +61 2 8814 4000
Bella Vista NSW 2153
Norwest Business Park
5 Irvine Place
written consent is prohibited
See Notes
Modifying or Distributing without
Engineering Pty Ltd. Copying,
3.
intellectual property of Actron
This drawing always remains the
ActronAir Pty Ltd
FOLD
7.
3
1.
HOLE DIAMETER
0.5 / m
0.1/~0
2.
FLAT PATTERN
4.
ANGLES & SQUARENESS
0.5 / m
5.
1
GENERAL TOLERANCES
(UNLESS OTHERWISE SPECIFIED)
ALL TUBES
UNLESS OTHERWISE SPECIFIED
3rd ANGLE PROJECTION.
1.
DIMENSIONS IN MILLIMETRES.
2.
DO NOT SCALE.
3.
TUBE ENDS MUST BE ROUND AND OF FULL
4.
DIAMETER.
TUBE MUST BE CLEAN AND FREE FROM
5.
BURRS INSIDE AND OUTSIDE AND SUITABLE
OF FOR SOLDERING.
ALL BENDS 90 .
6.
ALL SHEETMETAL'S DIMENSIONS OUTISDE.
A
A
B
Removal Order:
Pull-Out a bit
Pull-Down to remove
Access Panel-Electrical
A
B
THIRD ANGLE
PROJECTION
Drawing Release
D
E
F
C
B
A
3
2
1
5
C
D
4
6
7
8
A
B
ASSY CASING
8011-652-RENDER
30/07/2013
NM
See Notes
A3
SHEET 1 OF 1
N.T.S
DRAWING NO.
MATERIAL:
DESCRIPTION:
DATE
DRAWN BY:
APPROVED BY:
SCALE:
DRAWN DATE:
DESCRIPTION
FINISH:
REV
30/07/2013
DR
PCR
N/A
F
E
REV.
01
NM
ASS
EMBLY
8011-
652-RE
NDE
R
BY
A.B.N. 34 002 767 240
PH. +61 2 8814 4000
Bella Vista NSW 2153
Norwest Business Park
5 Irvine Place
written consent is prohibited
See Notes
Modifying or Distributing without
Engineering Pty Ltd. Copying,
3.
intellectual property of Actron
This drawing always remains the
ActronAir Pty Ltd
FOLD
7.
3
1.
HOLE DIAMETER
0.5 / m
0.1/~0
2.
FLAT PATTERN
4.
ANGLES & SQUARENESS
0.5 / m
5.
1
GENERAL TOLERANCES
(UNLESS OTHERWISE SPECIFIED)
ALL TUBES
UNLESS OTHERWISE SPECIFIED
3rd ANGLE PROJECTION.
1.
DIMENSIONS IN MILLIMETRES.
2.
DO NOT SCALE.
3.
TUBE ENDS MUST BE ROUND AND OF FULL
4.
DIAMETER.
TUBE MUST BE CLEAN AND FREE FROM
5.
BURRS INSIDE AND OUTSIDE AND SUITABLE
OF FOR SOLDERING.
ALL BENDS 90 .
6.
ALL SHEETMETAL'S DIMENSIONS OUTISDE.
01
Earth
Cable
Remove
Access Panel
THIRD ANGLE
PROJECTION
Drawing Release
D
E
F
C
B
A
3
2
1
5
C
D
4
6
7
8
A
B
ASSY CASING
8011-652-RENDER
30/07/2013
NM
See Notes
A3
SHEET 1 OF 1
N.T.S
DRAWING NO.
MATERIAL:
DESCRIPTION:
DATE
DRAWN BY:
APPROVED BY:
SCALE:
DRAWN DATE:
DESCRIPTION
FINISH:
REV
30/07/2013
DR
PCR
N/A
F
E
REV.
01
NM
ASS
EMBLY
8011
-652-
REN
DER
BY
A.B.N. 34 002 767 240
PH. +61 2 8814 4000
Bella Vista NSW 2153
Norwest Business Park
5 Irvine Place
written consent is prohibited
See Notes
Modifying or Distributing without
Engineering Pty Ltd. Copying,
3.
intellectual property of Actron
This drawing always remains the
ActronAir Pty Ltd
FOLD
7.
3
1.
HOLE DIAMETER
0.5 / m
0.1/~0
2.
FLAT PATTERN
4.
ANGLES & SQUARENESS
0.5 / m
5.
1
GENERAL TOLERANCES
(UNLESS OTHERWISE SPECIFIED)
ALL TUBES
UNLESS OTHERWISE SPECIFIED
3rd ANGLE PROJECTION.
1.
DIMENSIONS IN MILLIMETRES.
2.
DO NOT SCALE.
3.
TUBE ENDS MUST BE ROUND AND OF FULL
4.
DIAMETER.
TUBE MUST BE CLEAN AND FREE FROM
5.
BURRS INSIDE AND OUTSIDE AND SUITABLE
OF FOR SOLDERING.
ALL BENDS 90 .
6.
ALL SHEETMETAL'S DIMENSIONS OUTISDE.
01
Содержание CRQ2-14AS
Страница 35: ...THIS PAGE IS INTENTIONALLY LEFT BLANK ...