XVME-6500
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 79 -
http://www.acromag.com
- 79 -
www.acromag.com
8.1 Ordering Information
The XVME-9640 is only available in a lead-free solder model. When ordering
the XVME-9640-A-LF VMEbus CPU module, please select from and specify the
available connector options (A) as defined below:
•
Select the connector option (A):
✓
1: With RJ0, P3, P4, J8 Installed
✓
2: RJ0, P3, P4, J8 Not Installed
–
no mSATA
8.2 Hardware Information and Configuration
8.2.1 Switch SW1 Configuration
Table 8.2.1.a summarizes the functions, settings, and descriptions for dip
switch SW1.
Table 8.2.1.a: XVME-9640 Configuration Switch SW1
Configuration Switch SW1
Position
Function
Switch Setting
Description
1
Not Used
2
Not Used
3
Not Used
4
ORB GND
OFF (default)
ORB GND Isolated from
Digital GND
ON
ORB GND Tied to Digital
GND
SW1-4 is used to configure the isolation of the Front Panel (ORB) GND.
SW1-1, 1-2, and 1-3 are not used and can be in either position for normal
operation.
8.3 mSATA Module Installation
One or two full-size (51mm) mSATA modules may be installed using the
screws provided. In a high-vibration environment the addition of a
removable thread locker, such as Loctite 242, is recommended. For
installation of half-size (26.8mm) mSATA modules please consult factory.