3.1 Module Hardware Switch Configuration
3.1.1 Core Configuration Switch SW1
The configuration switch settings for SW1 depends on the revision of the
board. If the revision of the VPX6600 product is Rev G or earlier, use the SW1
switch settings shown in Table 3.1.a. If the revision of the VPX6600 product is
Rev H or later, use the SW1 switch settings shown in Table 3.1.b.
Table 3.1.a:
Core
Configuration
Switch SW1
Table 3.1.a summarizes the functions, settings, and descriptions for dip
switches SW1-1 thru SW1-4 for Rev G or earlier VPX6600 products.
Core Configuration Switch SW1
Position
Function
Switch Setting
Description
1
Reserved
OFF
Reserved
ON
Reserved
2
Expansion
Plane Interface
OFF
PCIe Interface
ON
SATA Interface
3
RTC Voltage
OFF
Coin-cell battery not used
ON
Coin-cell battery used as
RTC voltage
4
Not Used
OFF
Reserved
ON
Reserved
SW1-1 is reserved.
SW1-2 is used to select the interface on one of the expansion planes. The
expansion plane interface can either be one x4 PCIe connection or four
individual SATA III interfaces.
SW1-3 is used to configure the source of
the CPU’s RTC voltage. With a coin
-
cell battery installed, the CPU will use the coin-cell battery as the RTC voltage.
Turning SW1-3 on will use the VPX Battery input on Pin P1-G3 for the RTC
voltage.
WARNING: If SW1-3 is closed with a coin-cell battery installed, it will connect
the coin-cell to any voltage present on the VPX Battery pin on the VPX
connector P1-G3. The coin-cell battery must be removed before closing switch
SW1-3 if a voltage is supplied by the VPX backplane!
SW1-4 is unused.