VPX6600
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 42 -
http://www.acromag.com
- 42 -
https://www.acromag.com
6.5 Reliability Prediction
Table 6.5.a MTBF
MTBF (Mean Time Between Failure):
MTBF in hours using MIL-HDBK-217F,
FN2.
Per MIL-HDBK-217, Ground Benign, Controlled, G
B
G
C
Temperature MTBF (Hours)
MTBF (Years)
Failure Rate (FIT
1
)
25°C
187,627
21.4
5,329.7
40°C
125,853
14.4
7,945.8
1
FIT is Failures in 10
9
hours.
6.6 Installation of M.2 Expansion Card and Battery Replacement
6.6.1 VPX6600-LF (Air-Cooled) M.2 Expansion Card Installation
1.
Remove the 8 screws (M2 x 6mm) that secure the heatsink to the board.
Remove the heatsink.