VPX6600
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 63 -
http://www.acromag.com
- 63 -
https://www.acromag.com
7.3 Power Requirements
7.4 Environmental Considerations
7.4.1 Operating Temperature
-40°C to 85°C
1
1
Measured as Ambient Air Temperature. 300LFM minimum air-flow required. Designed to
meet this temperature specification.
7.4.2 Relative Humidity
5% to 95% Non-condensing
7.4.3 Vibration and Shock Standards
Vibration, Sinusoidal Operating:
Designed to comply with IEC 60068-2-6: 10-
500Hz, 5G, 2 Hours/axis
Vibration, Random Operating:
Designed to comply with IEC 60068-2-64: 10-
500Hz, 5G-rms, 2 Hours/axis
Shock, Operating:
Designed to comply with IEC 60068-2-27: 30G, 11ms half
sine, 50G, 3mS half sine, 18 shocks at 6 orientations for both test levels
7.4.4 EMC Directives
The VPX6600 is designed to comply with EMC Directive 2004/108/EC.
•
Immunity per EN 61000-6-2:
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
Radiated Field Immunity (RFI), per IEC 61000-4-3.
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4.
Surge Immunity, per IEC 61000-4-5.
Conducted RF Immunity (CRFI), per IEC 61000-4-6.
•
Emissions per EN 61000-6-4:
Enclosure Port, per CISPR 16.
Low Voltage AC Mains Port, per CISPR 16.
Note:
This is a Class A product