background image

VPX6600  

USER

’S MANUAL 

 

 

 

Acromag, Inc. Tel: 248-295-0310  

            - 44 -                                   

http://www.acromag.com  

- 44 - 

https://www.acromag.com 

 

 

Note: The washer should be under the M.2 expansion card as shown below. 

 

 

5.

 

Re-install the heatsink and secure with 8 screws (M2 x 6mm) 

 

 

VPX6600-LF (Air-cooled) M.2 expansion card installation complete. 

 

 

Содержание VPX6600

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ...dule USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0310 Email solutions acromag com Copyright 2019 Acromag Inc Printed in the USA Data and specifications are subject to change without notice 8501096E ...

Страница 3: ...CPU 9 1 6 2 Intel CM236 PCH 10 1 6 3 Intel I350 Quad Gigabit Ethernet Controller 11 1 6 4 Nuvoton NCT6106 Super I O 11 1 6 5 Atmel AT97SC3204 TPM 11 1 6 6 Avago PEX8714 PCIe Switch 11 1 6 7 M 2 Expansion Site 11 2 0 PREPARATION FOR USE 12 2 1 Unpacking and Inspecting 12 2 2 Installing into a VPX Backplane 13 3 0 HARDWARE INFORMATION AND CONFIGURATION 14 3 1 Module Hardware Switch Configuration 15 ...

Страница 4: ...guring the Video Memory 24 3 6 4 Video Display Options 24 3 6 5 Multi Stream Transport 24 3 7 Intel High Definition Audio 25 3 8 Storage I O 25 3 8 1 SATA 25 3 8 2 PCIe 25 3 9 Flexible I O 25 3 10 General I O 26 3 10 1 General Purpose I O GPIO 26 3 10 2 SMBus 26 3 10 3 Low Pin Count LPC 26 3 10 4 Serial Ports 27 3 10 5 USB 27 3 11 Gigabit Ethernet 28 3 11 1 Configuring PXE Boot 28 3 12 Real Time C...

Страница 5: ...5 2 1 CPU Throttling Hardware Controlled 32 3 15 2 2 Thermal Management OSPM Controlled 32 3 15 3 Memory Throttling 32 3 16 Watchdog 33 3 17 VPX Profile 33 3 17 1 Data Plane 34 3 17 2 Expansion Plane 34 3 17 3 Control Plane 34 4 0 BIOS INFORMATION AND CONFIGURATION 35 4 1 VPX6600 Special BIOS Features 35 4 2 Drivers and Utilities 35 5 0 SERVICE AND REPAIR 36 5 1 Service and Repair Assistance 36 5 ...

Страница 6: ...Cooled M 2 Expansion Card Installation 47 6 6 4 VPX6600 CC LF Conduction Cooled Battery Replacement 52 6 7 Certificate of Volatility 56 7 0 VPX6600 RTM REAR TRANSITION ACCESSORY MODULE 57 7 1 Ordering Information 57 7 2 Connector Information 57 7 2 1 VPX Backplane Connectors 57 7 2 1 1 RP0 VPX Connector 57 7 2 1 2 RP1 VPX Connector 58 7 2 1 3 RP2 VPX Connector 58 7 2 2 I O Connectors 58 7 2 2 1 J3...

Страница 7: ... www acromag com 7 3 Power Requirements 63 7 4 Environmental Considerations 63 7 4 1 Operating Temperature 63 7 4 2 Relative Humidity 63 7 4 3 Vibration and Shock Standards 63 7 4 4 EMC Directives 63 7 5 Reliability Prediction 64 7 6 Certificate of Volatility 65 REVISION HISTORY 66 ...

Страница 8: ...p current the information contained in this manual No part of this manual may be copied or reproduced in any form without the prior written consent of Acromag 1 2 1 Trademark Trade Name and Copyright Information 2019 by Acromag Incorporated All rights reserved Acromag and Xembedded are registered trademarks of Acromag Incorporated All other trademarks registered trademarks trade names and service ...

Страница 9: ...lly and thermally robust mechanism Extended temperature models are available for operating in a 40 C to 85 C range A large amount of I O is available as summarized in Section 6 2 below The VPX6600 contains an M 2 expansion card slot to provide on board storage capabilities The M 2 slot supports the use of SATA III and PCIe Gen 3 storage drives A two digit LED display is available for Power ON Self...

Страница 10: ...tforms Volume 1 of 2 May 2016 http www intel com content www us en processors core 6th gen core family mobile h processor lines datasheet vol 1 html 1 5 Ordering Information The VPX6600 ordering options are given in the following table Model Number Description Temp Range VPX6600 LF Air cooled 3U VPX CPU Module 0 C to 70 C VPX6601 LF Air cooled 3U VPX CPU Module No Battery 0 C to 70 C VPX6600 CC LF...

Страница 11: ...hics and contains direct interfaces for DDR4 DDI and PCIe x16 In addition the Direct Media Interface DMI is used to connect to the CM236 Platform Control Hub PCH DDR4 SDRAM Two SODIMM sockets support up to 32GB of DDR4 ECC at 2133MHz Dual channel mode is used with the two SODIMMs The SODIMMs are attached to the module firmly with screws and surrounded by heat sink material to provide a robust mech...

Страница 12: ...t The fourth is connected to the M 2 expansion slot SATA Gen3 7 There are seven SATA III ports on the VPX6600 All the ports are configurable as SATA ports or PCIe lanes Two are connected to the P2 backplane connector One is connected to the M 2 expansion site The remaining 4 are connected to the expansion plane fat pipe on the VPX backplane USB 3 0 4 There are four USB 3 0 ports on the VPX6600 Two...

Страница 13: ...ntegrated security module that implements version 1 2 of the Trusted Computing Group TCG specification for Trusted Platform Modules TPM The TPM includes a cryptographic accelerator capable of computing a 2048 bit RSA signature in 200ms and a 1024 bit RSA signature in 40ms Performance of the SHA 1 accelerator is 20μs per 64 byte block 1 6 6 Avago PEX8714 PCIe Switch The Avago PEX8714 is a 12 lane 5...

Страница 14: ...uct near strong electrostatic electromagnetic magnetic or radioactive fields unless the device is contained within its original manufacturer s packaging Be aware that failure to comply with these guidelines will void the Acromag Limited Warranty 2 1 Unpacking and Inspecting Upon receipt of this product inspect the shipping carton for evidence of mishandling during transit If the shipping carton is...

Страница 15: ...he VPX chassis Disconnect the power cable 2 Verify that all DIP switch settings are correct 3 Verify that the card cage slot is clear and accessible 4 Install the VPX6600 in the card cage by centering the unit on the guides in the slots P0 connector facing up Push the board slowly toward the rear of the chassis until the VPX connectors engage The board should slide freely in the guides WARNING Do ...

Страница 16: ...VPX6600 USER S MANUAL Acromag Inc Tel 248 295 0310 14 http www acromag com 14 https www acromag com 3 0 HARDWARE INFORMATION AND CONFIGURATION Figure 3 1 1 VPX6600 Top View right Bottom View left ...

Страница 17: ...OFF Reserved ON Reserved 2 Expansion Plane Interface OFF PCIe Interface ON SATA Interface 3 RTC Voltage OFF Coin cell battery not used ON Coin cell battery used as RTC voltage 4 Not Used OFF Reserved ON Reserved SW1 1 is reserved SW1 2 is used to select the interface on one of the expansion planes The expansion plane interface can either be one x4 PCIe connection or four individual SATA III interf...

Страница 18: ...transparent mode on the PEX8714 PCIe switch Non transparent mode provides the ability to use multiple processors in the same system SW1 3 is used to select the interface on one of the expansion planes The expansion plane interface can either be one x4 PCIe connection or four individual SATA III interfaces SW1 4 is used to configure the source of the CPU s RTC voltage With a coin cell battery insta...

Страница 19: ... for dip switch SW2 Core Configuration Switch SW2 Function Switch Setting Description FRU Voltage Select 1 2 FRU uses 3 3V 2 3 FRU uses 3 3V_AUX Not Used 4 5 Reserved 5 6 Reserved SW2 1 is a single pole dual throw switch used to select the voltage source for the following devices FRU EEPROM FRU Temperature Sensor When configured to use the auxiliary 3 3V supply these devices can still be operated ...

Страница 20: ...MOS Reset OFF Normal Operation ON Clear RTC CMOS 2 Reserved OFF Normal Operation ON Reserved 3 Reserved OFF Normal Operation ON Reserved 4 Reserved OFF Normal Operation ON Reserved SW3 1 is used to clear the Battery backed RTC CMOS Battery backed SRAM To clear the CMOS SRAM close SW3 1 momentarily and then open it again The switch must be in the open position for normal operation SW3 2 is reserved...

Страница 21: ...his is accomplished by the CPU automatically underclocking its frequency to maintain a power level at the set limit Note Once the minimum frequency of 800MHz is reached the programmed limit could be exceeded Extremely large workloads have a realistic minimum power of around 20W However light to medium workloads can effectively maintain a power limit as low as 5 10W There are two programmable CPU l...

Страница 22: ... 2 3 Power Management The VPX6600 module uses the Advanced Configuration and Power Interface ACPI 3 0 standard to provide user managed power via the operating system contingent upon the carrier board selected The Advanced Configuration and Power Interface ACPI provides an open standard for device configuration and power management by the operating system More details about this feature are provide...

Страница 23: ...rations More details about this feature are provided in Aptio Skylake Core BIOS Manual 3 4 Platform Controller Hub PCH The Intel C230 Series CM236 PCH provides extensive I O support as listed below PCIe Gen3 x4 4 There are three PCIe Gen3 ports of x4 width The first is connected to the Intel I350 Quad Gigabit Ethernet Controller The second is connected to the PEX8714 PCIe switch The third is conne...

Страница 24: ...0x1200 60Hz 3 6 1 Digital Display Interfaces The Intel Gen6 Skylake CPU used on the VPX6600 CPU module integrates three digital display ports B C and D that support DisplayPort HDMI or DVI interfaces DisplayPort can be configured to use 1 2 or 4 lanes depending on the bandwidth requirements and the link data rate of the RBR 1 62 GT s HBR 2 7 GT s and HBR2 5 4 GT s All three ports support DP which ...

Страница 25: ... provided for transmitting uncompressed digital audio and video signals from DVD players set top boxes and other audio visual sources to television sets projectors and other video displays It can carry high quality multi channel audio data and all standard and high definition consumer electronics video formats The HDMI display interface connecting the processor and display devices uses transition ...

Страница 26: ...specific primary display refer to Aptio Skylake Core BIOS Manual 3 6 3 Configuring the Video Memory To configure the video memory refer to Aptio Skylake Core BIOS Manual 3 6 4 Video Display Options The VPX6600 supports three simultaneous independent displays Display mode choices when using multiple monitors include Single display in which one port is activated to display the output on one device C...

Страница 27: ... legacy mode Therefore AHCI software is required The SATA features support The SATA hard disk drives solid state drives SSD and CD ROM DVD ROM drives AHCI and RAID 0 1 5 and 10 modes Data transfer rates of up to 6 0Gbps To configure SATA operation refer to Aptio Skylake Core BIOS Manual 3 8 2 PCIe In addition to SATA two of the PCIe x4 ports can use the NVMe protocol to connect to Intel PCIe Stora...

Страница 28: ...w to Table 3 10 2 a SMBus I2C Address Table below for additional information SMBus ADDR Function 0x32 DIMMA TEMP 0x34 DIMMA TEMP 0x5A NCT6016 Super I O 0xA0 Acro Express ID EEPROM 0xA2 DIMMA SPD 0xA4 DIMMB SPD 0x49 I350 Ethernet Controller 0x4 PCA9500 I O Expander 0xA PCA9500 EEPROM 0x9 TMP75 Temp Sensor Note Slave addresses of FRU devices PCA9500 TMP75 are slot dependent based on VPX Geographical...

Страница 29: ...sible Host Controller Interface xHCI controller to support the four USB 3 0 ports and the two USB 2 0 ports USB 3 0 ports support up to 5Gbps and USB 2 0 supports up to 480Mbps Note that EHCI mode is no longer supported which may affect the installation of some operating systems These USB features support USB hard disk drives flash drives floppy disk drives and CD ROM DVD ROM drives Super speed hi...

Страница 30: ...and runs on a 32 768 KHz crystal with a 3V battery The RTC performs two key functions It keeps track of the time of day and It stores system data even after powering down the system Note After the RTC battery is removed from the board with it otherwise unpowered the last BIOS settings will be retained for approximately 80 minutes by an onboard supercap After that the settings will be lost unless t...

Страница 31: ...red For further information on disabling support for this technology refer to Aptio Skylake Core BIOS Manual 3 14 2 Enhanced Intel SpeedStep Technology EIST The Enhanced Intel SpeedStep Technology EIST used by this processor enables very high performance while also meeting power conservation needs When EIST is enabled the clock frequency of the CPU is dynamically changed in response to the CPU loa...

Страница 32: ...aster than its rated operating frequency render clock if it is operating below power temperature and current limits The Intel Turbo Boost Technology feature is designed to increase performance of both multi threaded and single threaded workloads The processor supports a Turbo mode in which the processor can use the thermal capacity associated with the package and run at power levels higher than TD...

Страница 33: ...ology 3 14 8 Intel Configurable TDP Technology Intel Configurable TDP Technology cTDP allows users to reconfigure the 45W thermal design power TDP level of the E3 1505M CPU down to 35W in systems where a lower amount of power is available or a smaller thermal solution is required For further information on configuring the TDP levels refer to Aptio Skylake Core BIOS Manual 3 15 Thermal Management T...

Страница 34: ...ture of 100 C If throttling is not enough to keep the processor s Tj below the catastrophic temperature limit of 105 C The THERMTRIP signal will be sent and The voltage supply to the processor will be turned off within 500ms to prevent permanent silicon damage 3 15 2 2 Thermal Management OSPM Controlled The active and passive trip points are configured using the system Bios For information on how ...

Страница 35: ...n the Watchdog feature refer to Aptio Skylake Core BIOS Manual 3 17 VPX Profile The VPX6600 is designed to be used in OpenVPX module profile MOD3 PAY 1F2F2U 16 2 2 4 This module profile complies with OpenVPX slot profile SLT3 PAY 1F2F2U 14 2 2 shown in Figure 3 17 a below This module profile defines one PCIe Gen 2 fat pipe connection to be used as a Data Plane two PCIe Gen 2 fat pipes to be used a...

Страница 36: ...ions to adjacent slots in the system The first Expansion Plane connection uses PCIe lanes from the PEG interface on the CPU The PEG interface is traditionally used for external graphics but supports any PCIe device The second Expansion Plane connection uses Flexible I O from the PCH The interface can be configured to be a x4 PCIe connection or four individual SATA III ports using switch SW1 2 3 17...

Страница 37: ...owing hardware configuration options are available in the Acromag menu of the BIOS setup Utility GPOUT x Output Level Sets the corresponding General Purpose Output level to Low or High The default is Low User LED x Output Level Sets the corresponding User LED output level to Low or High The LED is on when the level is set to High The default is High Select COMx Mode Sets the corresponding COM port...

Страница 38: ...ure that all of the procedures in the Preparation for Use section have been followed Also refer to the documentation for the module to verify that it is correctly configured Replacement of the module with one that is known to work correctly is a good technique to isolate a faulty module 5 3 Where to Get Help If the problem persists the next step should be to visit the Acromag worldwide web site at...

Страница 39: ...PCIE_DP_RX0_N GND PCIE_DP_TX0_P PCIE_DP_TX0_N GND GDISCRETE1 2 GND PCIE_DP_RX1_P PCIE_DP_RX1_N GND PCIE_DP_TX1_P PCIE_DP_TX1_N GND 3 PCIE_DP_RX2_P PCIE_DP_RX2_N GND PCIE_DP_TX2_P PCIE_DP_TX2_N GND VPX_VBAT 4 GND PCIE_DP_RX3_P PCIE_DP_RX3_N GND PCIE_DP_TX3_P PCIE_DP_TX3_N GND 5 SATA4_PCIE17_RX_P SATA4_PCIE17_RX_N GND SATA4_PCIE17_TX_P SATA4_PCIE17_TX_N GND SYS_CON 6 GND SATA5_PCIE18_RX_P SATA5_PCIE...

Страница 40: ..._TX0_P DPB_TX0_N GND 11 DPB_TX3_P DPB_TX3_N GND DPB_TX2_P DPB_TX2_N GND GPOUT2 12 GND COM1_RTS _485_TX COM1_TX GND DPB_CTRL_AUX_P DPB_CTRL_AUX_N GND 13 COM1_CTS _485_RX COM1_RX GND COM2_RTS _485_TX COM2_TX GND DPB_HPD 14 GND DPC_TX1_P DPC_TX1_N GND DPC_TX0_P DPC_TX0_N GND 15 DPC_TX3_P DPC_TX3_N GND DPC_TX2_P DPC_TX2_N GND DPC_HPD 16 GND COM2_CTS _485_RX COM2_RX GND DPC_CTRL_AUX_P DPC_CTRL_AUX_N GN...

Страница 41: ...ont panel PIN SIGNAL 1 5V 2 USB4_N 3 USB4_P 4 GND 5 USB4_SSRX_N 6 USB4_SSRX_P 7 GND 8 USB4_SSTX_N 9 USB4_SSTX_P This standard 20 pin Mini DisplayPort connector TE Connectivity 2129320 brings DisplayPort D out to the front panel PIN SIGNAL 1 GND 2 DPC_HPD 3 DPC_TX0_P 4 DPC_AUX_SEL 5 DPC_TX0_N 6 GND 7 GND 8 GND 9 DPC_TX1_P 10 DPC_TX3_P 11 DPC_TX1_N 12 DPC_TX3_N 13 GND 14 GND 15 DPC_TX2_P 16 DPC_CTRL...

Страница 42: ...ariables including the operating system application software and the components that the module is integrated with See notes below for defined variables used to measure the following power values 5V S0 Idle1 10 5W S0 Max2 55 5 72W S0 Typ3 52W 3 3V All Modes 4 3W 1 S0 Idle was measured with module operating at 23 C ambient with 300LFM airflow using Windows 8 1 Operating System idle at desktop with ...

Страница 43: ...system performance However an inadequate final thermal solution as the result of inadequate air flow or improper conduction mounting could result in continual CPU throttling which will greatly affect system performance 6 4 2 Relative Humidity 5 to 95 Non condensing 6 4 3 Vibration and Shock Standards Vibration Sinusoidal Operating Designed to comply with IEC 60068 2 6 10 500Hz 5G 2 Hours axis Vibr...

Страница 44: ...K 217F FN2 Per MIL HDBK 217 Ground Benign Controlled GBGC Temperature MTBF Hours MTBF Years Failure Rate FIT1 25 C 187 627 21 4 5 329 7 40 C 125 853 14 4 7 945 8 1 FIT is Failures in 109 hours 6 6 Installation of M 2 Expansion Card and Battery Replacement 6 6 1 VPX6600 LF Air Cooled M 2 Expansion Card Installation 1 Remove the 8 screws M2 x 6mm that secure the heatsink to the board Remove the heat...

Страница 45: ... http www acromag com 43 https www acromag com 2 Remove the shoulder screw 1 5mm Hex and washer 3 Install the M 2 expansion card into socket 4 Place the washer on the VPX board and carefully press down the M 2 expansion card and secure with shoulder screw ...

Страница 46: ... 0310 44 http www acromag com 44 https www acromag com Note The washer should be under the M 2 expansion card as shown below 5 Re install the heatsink and secure with 8 screws M2 x 6mm VPX6600 LF Air cooled M 2 expansion card installation complete ...

Страница 47: ...el 248 295 0310 45 http www acromag com 45 https www acromag com 6 6 2 VPX6600 LF Air Cooled Battery Replacement 1 Remove the 8 screws M2 x 6mm that secure the heatsink to the board Remove the heatsink 2 Install new battery with face up ...

Страница 48: ...600 USER S MANUAL Acromag Inc Tel 248 295 0310 46 http www acromag com 46 https www acromag com 3 Re install heatsink and secure with 8 screws M2 x 6mm VPX6600 LF Air cooled battery replacement is complete ...

Страница 49: ...0310 47 http www acromag com 47 https www acromag com 6 6 3 VPX6600 CC LF Conduction Cooled M 2 Expansion Card Installation 1 Remove the 4 screws M2 x 6mm that secure the two wedge locks to the board Remove the two wedge locks Wedge lock Wedge lock ...

Страница 50: ...cromag Inc Tel 248 295 0310 48 http www acromag com 48 https www acromag com 2 Remove the 6 flat head screws M2 x 6mm that secure the heatsink to the board Remove the heatsink 3 Remove the shoulder screw 1 5mm Hex and washer ...

Страница 51: ...cromag com 49 https www acromag com 4 Install the M 2 expansion card into socket 5 Place the washer on the VPX board and carefully press down the M 2 expansion card and secure with shoulder screw Note The washer should be under the M 2 expansion card as shown below ...

Страница 52: ...VPX6600 USER S MANUAL Acromag Inc Tel 248 295 0310 50 http www acromag com 50 https www acromag com 6 Re install the heatsink and secure with 6 flat head screws M2 x 6mm ...

Страница 53: ... 51 https www acromag com 7 Attach the 2 wedge locks to the bottom and secure with 4 screws located on the top VPX6600 CC LF Conduction cooled M 2 expansion card installation complete Wedge lock Wedge lock Ensure the screw heads on the wedge locks face the front of the board ...

Страница 54: ...8 295 0310 52 http www acromag com 52 https www acromag com 6 6 4 VPX6600 CC LF Conduction Cooled Battery Replacement 1 Remove the 4 screws M2 x 6mm that secure the two wedge locks to the board Remove the two wedge locks Wedge lock Wedge lock ...

Страница 55: ...ANUAL Acromag Inc Tel 248 295 0310 53 http www acromag com 53 https www acromag com 2 Remove the 6 flat head screws M2 x 6mm that secure the heatsink to the board Remove the heatsink 3 Install new battery with face up ...

Страница 56: ...VPX6600 USER S MANUAL Acromag Inc Tel 248 295 0310 54 http www acromag com 54 https www acromag com 4 Re install the heatsink and secure with 6 flat head screws M2 x 6mm ...

Страница 57: ...g com 55 https www acromag com 5 Attach the 2 wedge locks to the bottom and secure with 4 screws located on the top VPX6600 CC LF Conduction cooled battery replacement is complete Wedge lock Wedge lock Ensure the screw heads on the wedge locks face the front of the board ...

Страница 58: ... ON position Non Volatile Memory Does this product contain Non Volatile memory i e Memory of whose contents is retained when power is removed Yes No Type EEPROM Flash etc Flash Size 16 Mbytes User Modifiable Yes No Function Storage of Code and Data for system BIOS Process to Sanitize Clear Flash memory by erasing all sectors of the Flash Type EEPROM Flash etc EEPROM CPU ID EERPROM Size 256 bytes U...

Страница 59: ...orts via standard USB 2 0 connector Two USB 3 0 ports via standard USB 3 0 connector Two DisplayPort ports via standard Mini DisplayPort connector One Gigabit Ethernet port via standard RJ45 connector The following I O is available via internal connectors on the VPX6600 RTM Two SATA III ports via standard 7 pin SATA data connectors Two software selectable RS 232 RS 422 RS 485 Serial Ports are avai...

Страница 60: ...PIN1 12 GND USB2_P USB2_N GND USB1_SSTX_P USB1_SSTX_N GND 13 USB2_SSTX_P USB2_SSTX_N GND USB2_SSRX_P USB2_SSRX_N GND GPIN2 14 GND AGND_AUDIO LINEOUT_L GND AGND_AUDIO LINEIN_L GND 15 LINEOUT_R AGND_AUDIO GND LINEIN_R AGND_AUDIO GND GPOUT3 16 GND SATA2_RX_P SATA2_RX_N GND SATA2_TX_P SATA2_TX_N GND RP2 Wafer A B C D E F G 1 SATA3_RX_P SATA3_RX_N 3 3 V SATA3_TX_P SATA3_TX_N GND GPOUT4 2 GND DPB_TX1_P ...

Страница 61: ...B_TX2_P 16 DPB_CTRL_AUX_P 17 DPB_TX2_N 18 DPB_CTRL_AUX_N 19 GND 20 3 3V This standard 20 pin Mini DisplayPort connector JAE Electronics DP3R020SU32JQR400 brings DisplayPort C out to the front panel PIN SIGNAL 1 GND 2 DPC_HPD 3 DPC_TX0_P 4 DPC_AUX_SEL 5 DPC_TX0_N 6 GND 7 GND 8 GND 9 DPC_TX1_P 10 DPC_TX3_P 11 DPC_TX1_N 12 DPC_TX3_N 13 GND 14 GND 15 DPC_TX2_P 16 DPC_CTRL_AUX_P 17 DPC_TX2_N 18 DPC_CTR...

Страница 62: ... PIN SIGNAL 1 5V 2 USB1_N 3 USB1_P 4 GND 5 USB1_SSRX_N 6 USB1_SSRX_P 7 GND 8 USB1_SSTX_N 9 USB1_SSTX_P This standard 9 pin USB3 0 connector Molex 48404 003 brings USB Port 2 out to the front panel PIN SIGNAL 1 5V 2 USB2_N 3 USB2_P 4 GND 5 USB2_SSRX_N 6 USB2_SSRX_P 7 GND 8 USB2_SSTX_N 9 USB2_SSTX_P This standard 7 pin SATA connector Molex 67800 8005 brings SATA Port 2 out to an internal connector P...

Страница 63: ... 3 SATA3_TX_N 4 GND 5 SATA3_RX_N 6 SATA3_RX_P 7 GND This standard 4 pin USB2 0 connector Molex 67329 8001 brings USB Port 3 out to the front panel PIN SIGNAL 1 5V 2 USB3_N 3 USB3_P 4 GND This standard 4 pin USB2 0 connector Molex 67329 8001 brings USB Port 4 out to the front panel PIN SIGNAL 1 5V 2 USB4_N 3 USB4_P 4 GND This standard 8 pin Ethernet connector TE Connectivity 2 406549 1 brings Ether...

Страница 64: ...hen serial port is in RS 422 RS 485 mode This 10 pin standard 0 1 header TE Connectivity 5103310 1 is used for the COM2 serial port connection These signals can be accessed through a standard DB 9 connector by using a DB9M TO IDC10 SERIAL DTK cable PIN SIGNAL SIGNAL PIN 1 NC COM2_RX 1 2 3 COM2_RX NC 4 5 COM2_TX NC 6 7 COM2_TX 1 NC 8 9 GND GND 10 1 TX and RX only used when serial port is in RS 422 ...

Страница 65: ...ed to comply with IEC 60068 2 64 10 500Hz 5G rms 2 Hours axis Shock Operating Designed to comply with IEC 60068 2 27 30G 11ms half sine 50G 3mS half sine 18 shocks at 6 orientations for both test levels 7 4 4 EMC Directives The VPX6600 is designed to comply with EMC Directive 2004 108 EC Immunity per EN 61000 6 2 Electrostatic Discharge Immunity ESD per IEC 61000 4 2 Radiated Field Immunity RFI pe...

Страница 66: ... acromag com 7 5 Reliability Prediction Table 7 5 a MTBF MTBF Mean Time Between Failure MTBF in hours using MIL HDBK 217F FN2 Per MIL HDBK 217 Ground Benign Controlled GBGC Temperature MTBF Hours MTBF Years Failure Rate FIT1 25 C TBD TBD TBD 40 C TBD TBD TBD 1 FIT is Failures in 109 hours ...

Страница 67: ...c Size User Modifiable Yes No Function Process to Sanitize Type SRAM SDRAM etc Size User Modifiable Yes No Function Process to Sanitize Non Volatile Memory Does this product contain Non Volatile memory i e Memory of whose contents is retained when power is removed Yes No Type EEPROM Flash etc Size User Modifiable Yes No Function Process to Sanitize Type EEPROM Flash etc Size User Modifiable Yes No...

Страница 68: ...tion of M 2 Expansion Card and Battery Replacement The two washers have been replaced with one washer changed accordingly 31 MAY 2019 C JBO ARP Added new Batteryless products to the Ordering Information section 7 AUG 2019 D MDW MJO Added information about supported M 2 module lengths Updated SW1 switch tables to reflect updates for Rev H or later products 04 OCT 2019 E MDW MJO Updated MTBF Table S...

Страница 69: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Отзывы: