SERIES AP445 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 20 - http://www.acromag.com
- 20 -
www.acromag.com
Table 3.6: System Monitor
Register Map
Address
Status Register
0x00
Temperature
0x01
Vccint
0x02
Vccaux
0x20
Maximum Temperature
0x21
Maximum Vccint
0x22
Maximum Vccaux
0x24
Minimum Temperature
0x25
Minimum Vccint
0x26
Minimum Vccaux
Table 3.7 FPGA Voltage and
Temperature Range
Symbol
Minimum
Typical
Maximum
Vccint
0.95
1.0
1.05
Vccaux
1.71
1.8
1.89
Temperature
operating range
-40C
50-60C
100C
Firmware Revision Register (Read Only) – (BAR0 + 0x0000 0200)
This is a read only register. The ASCII code representing the current revision
of the MCS firmware file is readable from this location. For example, if the
firmware is at revision A, then this register will read 0x41 in the least
significant byte or B= 0x42, C=0x43, etc.