SERIES AP445 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 24 - http://www.acromag.com
- 24 -
www.acromag.com
6.0 SPECIFICATIONS
6.1 Physical
Height:
12.5 mm (0.4921 in)
Height defines Carrier to Module Maximum component height
Board Thickness
1.0 mm (0.03937 in)
AcroPack L x W: 70 mm x 30.00 mm
(2.76 in x 1.18 in)
Unit Weight (does not include shipping material):
AcroPack 0.314ounces (8.9g)
6.2 Power Requirements
6.3 Environmental Considerations
6.3.1 Operating Temperature
Model Number
Description
Temp Range
AP445E-LF
32 channel, isolated output module
-40
o
C to 85
o
C
1
Note 1:
An air cooled application with an AcroPack module will
require a minimum airflow of 200LFM.
6.3.2. Relative Humidity
The range of acceptable relative humidity is 5% to 95% non-condensing.
Summarized below are the expected current draws for each of the specified
power supply voltages.
Power Supply Voltage Current Draw
3.3 VDC +/- 5% 495mA typ (all outputs OFF)
675mA typ/800mA max (all outputs ON)
1.5 VDC +/- 5% Not Used
5.0 VDC +/- 5% Not Used
+12 VDC +/- 5% Not Used
-12 VDC +/- 5% Not Used
Summarized below are the operating temperature range, airflow
and other environmental requirements and applicable standards for
the AcroPack module.