SERIES AP445 ACROPACK 

 

USER

’S MANUAL 

 

 

 

 

 

 

 

Acromag, Inc. Tel: 248-295-0310  

          - 11 -                                   http://www.acromag.com  

- 11 - 

www.acromag.com 

 

 

 

 

43 

Reserved/isolation 

23 

12 

12 

46 

Field Output 19 

24 

37 

46 

45 

Field Output 20 

 

 

 

48 

Reserved/isolation 

 

 

 

47 

Reserved/isolation 

25 

13 

13 

50 

CSUP 

26 

38 

47 

49 

Field Output 21 

 

 

 

52 

Reserved/isolation 

 

 

 

51 

Reserved/isolation 

27 

14 

14 

54 

Field Output 22 

28 

39 

48 

53 

Field Output 23 

 

 

 

56 

Reserved/isolation 

 

 

 

55 

Reserved/isolation 

29 

15 

15 

58 

Field Output 24 

30 

40 

49 

57 

CCOM 

 

 

 

60 

Reserved/isolation 

 

 

 

59 

Reserved/isolation 

31 

16 

16 

62 

Field Output 25 

32 

41 

50 

61 

Field Output 26 

 

 

 

64 

Reserved/isolation 

 

 

 

63 

Reserved/isolation 

33 

17 

17 

66 

Field Output 27 

34 

42 

51 

65 

Field Output 28 

 

 

 

68 

Reserved/isolation 

 

 

 

67 

Reserved/isolation 

35 

18 

18 

70 

DSUP 

36 

43 

52 

69 

Field Output 29 

 

 

 

72 

Reserved/isolation 

 

 

 

71 

Reserved/isolation 

37 

19 

19 

74 

Field Output 30 

38 

44 

53 

73 

Field Output 31 

 

 

 

76 

Reserved/isolation 

 

 

 

75 

Reserved/isolation 

39 

20 

20 

78 

Field Output 32 

40 

45 

54 

77 

DCOM 

 

 

 

80 

Reserved/isolation 

 

 

 

79 

Reserved/isolation 

41 

21 

21 

82 

NC 

Содержание AcroPack AP445 Series

Страница 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Страница 2: ...Output Module USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0310 Fax 248 624 9234 Copyright 2016 Acromag Inc Printed in the USA Data and specificatio...

Страница 3: ...1 3 1 Ordering Information 5 1 3 2 Key Features 5 1 3 3 Key Features PCIe Interface 6 1 4 Signal Interface Products 6 1 5 Software Support 7 Windows 7 VxWorks 7 Linux 7 1 6 References 7 2 0 PREPARATIO...

Страница 4: ...AR0 48H 19 XADC Address Register Write Only BAR0 4CH 19 Table 3 6 System Monitor Register Map 20 Table 3 7 FPGA Voltage and Temperature Range 20 Firmware Revision Register Read Only BAR0 0x0000 0200 2...

Страница 5: ...TS 26 6 6 PCIe Bus Specifications 26 Table 6 6 PCIe Bus Data Rates 27 APPENDIX A 28 AP CC 01 Heatsink Kit Installation 28 APPENDIX B 31 Figure 1 AP445 Block Diagram 31 Figure 2 AP445 Digital Out to AP...

Страница 6: ...uced in any form without the prior written consent of Acromag 1 2 1 Trademark Trade Name and Copyright Information 2016 by Acromag Incorporated All rights reserved Acromag and Xembedded are registered...

Страница 7: ...range for models 40oC to 85oC AP CC 01 AcroPack Heatsink Conduction Cool Kit See Appendix A for installation instructions 1 3 2 Key Features High Channel Count Individual control of up to 32 SPST NO b...

Страница 8: ...compatible with those of the Acromag Model AP440 32 Channel Isolated Input Module for direct closed loop monitoring of the output states The AP445 also shares the same pinout used on the Acromag non i...

Страница 9: ...Acromag provides a software product sold separately consisting of VxWorks software This software Model APSW API VXW is composed of VxWorks real time operating system libraries for all AcroPack modules...

Страница 10: ...etic or radioactive fields unless the device is contained within its original manufacturer s packaging Be aware that failure to comply with these guidelines will void the Acromag Limited Warranty 2 1...

Страница 11: ...e the maximum operating temperature 2 3 Board Configuration Power should be removed from the board when installing AP modules cables termination panels and field wiring Model AP445 isolated output boa...

Страница 12: ...20 Reserved isolation 19 Reserved isolation 11 6 6 22 Field Output 9 12 31 40 21 Field Output 10 24 Reserved isolation 23 Reserved isolation 13 7 7 26 Field Output 11 14 32 41 25 Field Output 12 28 R...

Страница 13: ...Reserved isolation 29 15 15 58 Field Output 24 30 40 49 57 CCOM 60 Reserved isolation 59 Reserved isolation 31 16 16 62 Field Output 25 32 41 50 61 Field Output 26 64 Reserved isolation 63 Reserved is...

Страница 14: ...47 56 85 NC 88 Reserved isolation 87 Reserved isolation 45 23 23 90 NC 46 48 57 89 NC 92 Reserved isolation 91 Reserved isolation 47 24 24 94 NC 48 49 58 93 NC 96 Reserved isolation 95 Reserved isolat...

Страница 15: ...nd between each port and the AcroPack logic circuitry Field I O pinouts are arranged to be compatible with similar AcroPack models This model is directly loopback compatible with the Acromag Model AP4...

Страница 16: ...he pin assignments of this connector are standard for all AP modules according to the PCI Express MINI Card Electromechanical Specification REV 1 2 with exceptions shown in Table 2 2 and noted below T...

Страница 17: ...K 1 9 GND 10 N C UIM_DATA 1 7 CLKREQ 8 N C UIM_PWR 1 5 TCK COEX2 1 6 N C 1 5V 1 3 TMS COEX1 1 4 GND 1 N C WAKE 1 2 3 3V3 Note 1 Signals are not applicable for the AP445 implementation Pins are either...

Страница 18: ...nt The software also determines the configuration requirements of the PCIe card The system software accesses the configuration registers to determine how many blocks of memory space the module require...

Страница 19: ...ress map for the AP445 is shown in Table 3 2 Note that the base address for the board BAR0 in memory space must be added to the addresses shown to properly access these AP445 registers Register access...

Страница 20: ...00 Carrier Site A 001 Carrier Site B 010 Carrier Site C 011 Carrier Site D 7 to 3 Module Slot Location Bits These bits identify the slot location of the AP module in a system The Carrier may use backp...

Страница 21: ...6 of this register hold the address of the XADC register that is accessed Data bits 15 to 6 of this register hold the ADCcode temperature Vccint or Vccaux value Data bits 5 to 0 are not used Valid add...

Страница 22: ...mum Vccint 0x26 Minimum Vccaux Table 3 7 FPGA Voltage and Temperature Range Symbol Minimum Typical Maximum Vccint 0 95 1 0 1 05 Vccaux 1 71 1 8 1 89 Temperature operating range 40C 50 60C 100C Firmwar...

Страница 23: ...t Because the output lines of a single port share a common connection individual outputs are not isolated from each other within the same port However separate port commons are provided to facilitate...

Страница 24: ...ey conduct high currents however given the large number of channels on the board adequate air circulation must be maintained The SSR s do not contain any built in current limiting for their protection...

Страница 25: ...ervice Procedure CAUTION POWER MUST BE TURNED OFF BEFORE SERVICING BOARDS Before beginning repair be sure that all of the procedures in the Preparation for Use section have been followed Also refer to...

Страница 26: ...ion Temp Range AP445E LF 32 channel isolated output module 40oC to 85oC1 Note 1 An air cooled application with an AcroPack module will require a minimum airflow of 200LFM 6 3 2 Relative Humidity The r...

Страница 27: ...4 Vibration and Shock Standards The AcroPack passes the following Vibration and Shock standards Vibration Sinusoidal Operating Complies with IEC 60068 2 6 10 500Hz 5G 2 Hours axis Vibration Random Ope...

Страница 28: ...Leakage Current 1uA maximum Output ON Current Range 150mA maximum continuous up to 1A total per port Outputs are NOT current limited and may need external current limiting circuitry to ensure current...

Страница 29: ...er is 20 Bytes with data payload of 4 Bytes for our typical AcroPack For each 4 Byte data sample 24 Bytes are sent 10 4 M samples sec or 41 6 M Bytes sec or 0 332 G bit sec Note 3 For our typical Acro...

Страница 30: ...Tel 248 295 0310 28 http www acromag com 28 www acromag com Appendix A AP CC 01 Heatsink Kit Installation This example will show how to install the AP CC 01 Heatsink kit with an APCe7020 carrier AP CC...

Страница 31: ...ACK USER S MANUAL Acromag Inc Tel 248 295 0310 29 http www acromag com 29 www acromag com 1 Install two standoffs and secure with two screws 2 Install the AcroPack module 3 Install the Heatsink and se...

Страница 32: ...S AP445 ACROPACK USER S MANUAL Acromag Inc Tel 248 295 0310 30 http www acromag com 30 www acromag com 4 AP CC 01 Installation is complete Note Make sure the thermal pad is making contact with the FPG...

Страница 33: ...T 4 18V AP445 OUTPUT AP445 DIGITAL OUT TO AP440 DIGITAL INPUT WHEN INTERFACING DIGITAL OUTPUT LEVELS TO THE AP440 USE THE MODEL AP440 1 4V THRESHOLD AND ADJUST THE EXTERNAL PULLUP VALUE ACCORDINGLY 47...

Страница 34: ...CONNECTIONS AP445 CONNECTED AS A HOT SIDE SWITCH AP445 CONNECTED AS A LOW SIDE SWITCH AP445 CONNECTED AS A LOW SIDE SWITCH AP445 CONNECTED AS A HIGH HOT SIDE SWITCH NOTE THAT FOR LOOPBACK PURPOSES THE...

Страница 35: ...tize Power Down Type SRAM SDRAM etc Size User Modifiable Yes No Function Process to Sanitize Non Volatile Memory Does this product contain Non Volatile memory i e Memory of whose contents is retained...

Страница 36: ...tion 7 19 2016 Rev A ENZ MJO Rev A Release 8 02 2016 Rev B ENZ MJO Minor format changes carrier installation instructions added isolation voltage added and Firmware Revision Register added 10 11 2016...

Страница 37: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: