ASD SERIES INSTALLATION AND OPERATION MANUAL
7
TABLE 1
DRIVE ELECTRICAL RATINGS
Model No.
Part No.
Ac Line Input
Fuse or
Circuit
Breaker
Rating
(Amps)
Output
Horsepower
Selection
(Jumper J2)
1
Net
Weight
Volts AC
(50/60 Hz)
Phase
(Ф)
Maximum
Current
(Amps AC)
Voltage
Range
(Volts AC)
Maximum
Continuous
Load Current
(Amps/Phase)
Maximum
Horsepower
(HP (kW))
lbs kg
ASD-24D
928935
115
1
14.4
20
0
– 208/230
3.6
1 (0.75)
1
3/4 1/2 1/4 1/8 5.9 2.7
208/230
1
8.1
15
ASD-27D
928936
115
1
22
25
0
– 208/230
5.5
1½ (1.13)
─
1½
2
1 3/4 1/2 10.3 4.7
208/230
1
16.7
20
0
– 208/230
6.7
2 (1.5)
2
A
B
C
D
E
ASD-29
928938
208/230
1
16.7
20
0
– 208/230
6.7
2 (1.5)
─
2
3
1½ 1 3/4
10.3 4.7
3
11.7
15
0
– 208/230
9.0
3 (2.25)
3
3
ASD-29 (1P)
928937
208/230
1
20.5
25
0
– 208/230
9.0
4
3 (2.25)
3
2 1½ 1 3/4
ASD-45
928940
400/460
3
7.2
10
0
– 400/460
5
5.5
3 (2.25)
3
2 1½ 1 3/4
ASD-48
928941
400/460
3
11
15
0
– 400/460
5
8.3
5 (3.75)
5
3
2 1½ 1
Notes: 1. Bold indicates factory setting. ASD-24D: J2 is labeled "1", "3/4", "1/2", "1/4", "1/8". ASD-27D: J2 is labeled "2", "1½", "1", "3/4", "1/2".
ASD-29, (29 (1P), 45, 48: J2 is labeled "A", "B", "C", "D", "E". 2. ASD-27D: Rated 1½ HP maximum with 115 Volt AC Line input and 2 HP
maximum with 208/230 Volt AC Line input. 3. ASD-29: Rated 2 HP maximum with 1-phase AC Line input and 3 HP maximum with 3-phase AC
Line input. 4. ASD-29 (1P): Rated 9 Amps at 35 °C / 95 °F and derated to 8.3 Amps at 40 °C / 104 °F. For ambient temperatures above
40 °C / 104 °F, the drive is derated 2.5% per °C. 5. ASD-45, 48: Rated 0
– 400 Volts AC for 50 Hz motor operation and 0 – 460 Volts AC for
60 Hz motor operation.
TABLE 2
DRIVE GENERAL PERFORMANCE SPECIFICATIONS
Description
Specification
Factory Setting
115 Volt AC Line Input Voltage Operating Range (Volts AC)
115 (±15%)
—
208/230 Volt AC Line Input Voltage Operating Range
(Volts AC)
208 (-15%) / 230 (+15%)
—
400/460 Volt AC Line Input Voltage Operating Range
(Volts AC)
380 (-15%)
– 460 (+15%)
—
Maximum Load (% Current Overload for 2 Minutes)
150
—
Switching Frequency (kHz) (Jumper J12)
8, 12
8
Signal Following Input Voltage Range
(Volts DC)
0
– 10
—
Output Frequency Resolution (Bits, Hz)
10, 0.06
—
Maximum Speed Trimpot (MAX) Range (% Frequency Setting)
70
– 110
100
Minimum Speed Trimpot (MIN) Range (% Frequency Setting)
0
– 40
0
Acceleration Trimpot (ACCEL) Range (Seconds)
0.3
– 20
1.5
Deceleration Trimpot (DECEL) Range (Seconds)
0.3
– 20
1.5
DC Injection Brake (DECEL) (Seconds)
0.3
– 6.0
1.7
Boost Trimpot (BOOST) Range (Volts)
0
– 30
5
Current Limit Trimpot (CL) Range (% Full Load)
40
– 200
160
Jog Trimpot (JOG) Range (% Frequency Setting)
0
– 100
35
Slip Compensation Trimpot (COMP) Range at Drive Rating (Volts/Hz)
0
– 3
1.5
Motor Frequency Setting (Hz) (Jumper J5)
50, 60
60
Output Frequency Multiplier (1X, 2X) (Jumper J4)
1
1, 2
1
Minimum Operating Frequency at Motor (Hz)
1
—
Speed Range (Ratio)
60:1
—
Speed Regulation (30:1 Speed Range, 0
– Full Load) (% Base Speed)
2
2.5
—
Overload Protector Trip Time for Stalled Motor (Seconds)
6
—
Undervoltage/Overvoltage Trip Points for 115 Volt AC Line Input (± 5%) (Volts AC)
3
76
– 141
—
Undervoltage/Overvoltage Trip Points for 208/230 Volt AC Line Input (± 5%) (Volts AC)
3
151
– 282
—
Undervoltage/Overvoltage Trip Points for 400/460 Volt AC Line Input (± 5%) (Volts AC)
3
302
– 567
—
Run/Fault Relay Output Contact Rating (Amps at 30 Volts DC, 125 Volts AC, 250 Volts AC)
1, 0.5, 0.25
—
Operating Temperature Range (°C / °F)
0
– 40 / 32 – 104
—
Operating Humidity Range (% Relative, Non-Condensing)
0
– 95
—
Storage Temperature (°C / °F)
-2.5
– +85 / -13 – +185
—
Notes: 1. Allows the motor to operate up to two times the rated RPM. Constant horsepower will result when operating the drive in the "X2" mode
above the motor rated frequency. 2. Dependent on motor performance. 3. Do not operate the drive outside the specified AC Line input voltage
operating range.