ASD SERIES INSTALLATION AND OPERATION MANUAL 

TABLE 1 

DRIVE ELECTRICAL RATINGS 

Model No. 

Part No. 

Ac Line Input 

Fuse or 

Circuit 

Breaker 

Rating 

(Amps) 

Output 

Horsepower 

Selection 

 (Jumper J2)

1

 

Net 

Weight 

Volts AC 

(50/60 Hz) 

Phase 

(Ф) 

Maximum 

Current 

(Amps AC) 

Voltage 

Range 

(Volts AC) 

Maximum 

Continuous 

Load Current 

(Amps/Phase) 

Maximum 

Horsepower 

(HP (kW)) 

lbs  kg 

ASD-24D 

928935 

115 

14.4 

20 

– 208/230 

3.6 

1 (0.75) 

3/4  1/2  1/4  1/8  5.9  2.7 

208/230 

8.1 

15 

ASD-27D 

928936 

115 

22 

25 

– 208/230 

5.5 

1½ (1.13) 

─ 

2

 

1  3/4  1/2  10.3  4.7 

208/230 

16.7 

20 

– 208/230 

6.7 

2 (1.5) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASD-29 

928938 

208/230 

16.7 

20 

– 208/230 

6.7 

2 (1.5) 

─ 

2

3

 

1½  1  3/4 

10.3  4.7 

11.7 

15 

– 208/230 

9.0 

3 (2.25) 

3

3

 

ASD-29 (1P) 

928937 

208/230 

20.5 

25 

– 208/230 

9.0

4

 

3 (2.25) 

2  1½  1  3/4 

ASD-45 

928940 

400/460 

7.2 

10 

– 400/460

5

 

5.5 

3 (2.25) 

2  1½  1  3/4 

ASD-48 

928941 

400/460 

11 

15 

– 400/460

5

 

8.3 

5 (3.75) 

2  1½  1 

Notes: 1. Bold indicates factory setting. ASD-24D: J2 is labeled "1", "3/4", "1/2", "1/4", "1/8". ASD-27D: J2 is labeled "2", "1½", "1", "3/4", "1/2". 
ASD-29,  (29  (1P),  45,  48: J2  is  labeled  "A",  "B", "C",  "D",  "E".  2.  ASD-27D:  Rated  1½  HP  maximum  with  115  Volt  AC  Line  input  and  2  HP 
maximum with 208/230 Volt AC Line input. 3. ASD-29: Rated 2 HP maximum with 1-phase AC Line input and 3 HP maximum with 3-phase AC 
Line  input.  4.  ASD-29  (1P):  Rated  9  Amps  at  35  °C  /  95  °F  and  derated  to  8.3  Amps  at  40  °C  /  104  °F.  For  ambient  temperatures  above                  
40 °C / 104 °F, the drive is derated 2.5% per °C. 5. ASD-45, 48: Rated 0 

– 400 Volts AC for 50 Hz motor operation and 0 – 460 Volts AC for    

60 Hz motor operation. 

 
 

TABLE 2 

DRIVE GENERAL PERFORMANCE SPECIFICATIONS 

Description 

Specification 

Factory Setting 

115 Volt AC Line Input Voltage Operating Range (Volts AC)

 

115 (±15%) 

— 

208/230 Volt AC Line Input Voltage Operating Range

 

(Volts AC) 

208 (-15%) / 230 (+15%) 

— 

400/460 Volt AC Line Input Voltage Operating Range

 

(Volts AC) 

380 (-15%) 

– 460 (+15%) 

— 

Maximum Load (% Current Overload for 2 Minutes) 

150 

— 

Switching Frequency (kHz) (Jumper J12) 

8, 12 

Signal Following Input Voltage Range

 

(Volts DC) 

– 10 

— 

Output Frequency Resolution (Bits, Hz) 

10, 0.06 

— 

Maximum Speed Trimpot (MAX) Range (% Frequency Setting) 

70 

– 110 

100 

Minimum Speed Trimpot (MIN) Range (% Frequency Setting) 

– 40 

Acceleration Trimpot (ACCEL) Range (Seconds) 

0.3 

– 20 

1.5 

Deceleration Trimpot (DECEL) Range (Seconds) 

0.3 

– 20 

1.5 

DC Injection Brake (DECEL) (Seconds) 

0.3 

– 6.0 

1.7 

Boost Trimpot (BOOST) Range (Volts) 

– 30 

Current Limit Trimpot (CL) Range (% Full Load) 

40 

– 200 

160 

Jog Trimpot (JOG) Range (% Frequency Setting) 

– 100 

35 

Slip Compensation Trimpot (COMP) Range at Drive Rating (Volts/Hz) 

– 3 

1.5 

Motor Frequency Setting (Hz) (Jumper J5) 

50, 60 

60 

Output Frequency Multiplier (1X, 2X) (Jumper J4)

 1

 

1, 2 

Minimum Operating Frequency at Motor (Hz) 

— 

Speed Range (Ratio) 

60:1 

— 

Speed Regulation (30:1 Speed Range, 0 

– Full Load) (% Base Speed)

 2

 

2.5 

— 

Overload Protector Trip Time for Stalled Motor (Seconds) 

— 

Undervoltage/Overvoltage Trip Points for 115 Volt AC Line Input (± 5%) (Volts AC)

 3

 

76 

– 141 

— 

Undervoltage/Overvoltage Trip Points for 208/230 Volt AC Line Input (± 5%) (Volts AC)

 3

 

151 

– 282 

— 

Undervoltage/Overvoltage Trip Points for 400/460 Volt AC Line Input (± 5%) (Volts AC)

 3

 

302 

– 567 

— 

Run/Fault Relay Output Contact Rating (Amps at 30 Volts DC, 125 Volts AC, 250 Volts AC) 

1, 0.5, 0.25 

— 

Operating Temperature Range (°C / °F) 

– 40 / 32 – 104 

— 

Operating Humidity Range (% Relative, Non-Condensing) 

– 95 

— 

Storage Temperature (°C / °F) 

-2.5 

– +85 / -13 – +185 

— 

Notes: 1. Allows the motor to operate up to two times the rated RPM. Constant horsepower will result when operating the drive in the "X2" mode 
above the motor rated frequency. 2. Dependent on motor performance. 3. Do not operate the drive outside the specified AC Line input voltage 
operating range.

 

Содержание ACME SYNC ASD Series

Страница 1: ...TE The drive is factory set for 60 Hz motors For 50 Hz motors see Section 10 4 on page 15 See Safety Warnings on page 5 LISTED IND CONT EQ 70ZA 3 RoHS This Manual Covers Models ASD 24D 27D 29 29 1P 45...

Страница 2: ...Hz Motor Operation 15 10 4 2 Setting the Drive for Two Times the Rated Motor RPM 15 10 5 Boost Mode Selection J6 16 10 6 Braking Mode Selection J7 16 10 7 Run Fault Output Relay Operation Selection J...

Страница 3: ...oost Mode Selection J6 16 19 Braking Mode Selection J7 16 20 Run Fault Output Relay Operation Selection J8 16 21 Stop Contact Type Selection J9 16 22 Torque Mode Selection J10 16 23 Switching Frequenc...

Страница 4: ...lt AC Line input and 2 HP maximum with 208 230 Volt AC Line input ASD 29 Designed to accept 1 phase Terminals L1 L2 or 3 phase Terminals L1 L2 L3 AC Line input Rated for 208 230 Volt AC Line input onl...

Страница 5: ...tilated 3 phase AC induction motors will overheat if used beyond a limited speed range at full torque Therefore it is necessary to reduce motor load as speed is decreased Note Some fan cooled motors c...

Страница 6: ...rial Duty Die Cast Aluminum Case with Hinged Cover Available in dark gray finish or FDA approved white finish Simple to Operate Does not require programming Uses trimpots and jumpers which are factory...

Страница 7: ...put Voltage Operating Range Volts AC 208 15 230 15 400 460 Volt AC Line Input Voltage Operating Range Volts AC 380 15 460 15 Maximum Load Current Overload for 2 Minutes 150 Switching Frequency kHz Jum...

Страница 8: ...on See Section 10 2 on page 15 5 Jumper J5 Motor Frequency selection See Section 10 4 on page 19 6 Jumper J12 Switching Frequency and GFCI selection See Section 10 11 on page 16 7 Jumper J6 Adjustable...

Страница 9: ...ee Section 10 5 on page 16 5 Jumper J4 Frequency Multiplier selection See Section 10 4 on page 15 6 Jumper J7 Regeneration or DC Injection Braking See Section 10 6 on page 16 7 Jumper J5 Motor Frequen...

Страница 10: ...15 4 Jumper J6 Adjustable Boost selection See Section 10 5 on page 16 5 Jumper J4 Frequency Multiplier selection See Section 10 4 on page 15 6 Jumper J7 Regeneration or DC Injection Braking See Sectio...

Страница 11: ...should be taken to avoid extreme hazardous locations where physical damage can occur When mounting the drive in an enclosure the enclosure should be large enough to allow for proper heat dissipation s...

Страница 12: ...ASD SERIES INSTALLATION AND OPERATION MANUAL 12 FIGURE 8 ASD 27D 29 29 1P 45 48 MECHANICAL SPECIFICATIONS Inches mm Tighten these screws in the sequence shown to 12 in lbs 14 kg cm...

Страница 13: ...gasket is slightly compressed The recommended tightening torque is 12 in lbs 14 kg cm do not overtighten See Figures 7 and 8 on pages 11 and 12 for the tightening sequence Application Note To avoid e...

Страница 14: ...G All equipment AC Line inputs must be disconnected from the AC power Connect all equipment AC power input lines together and connect them to the H V lead of the hi pot tester Connect the RETURN lead...

Страница 15: ...ut 10 3 AUTOMATIC RIDE THROUGH OR MANUAL START SELECTION J3 Jumper J3 is factory set to the A or AUTO position for Automatic Ride Through If the power is interrupted for up to 2 seconds the drive will...

Страница 16: ...ing Frequency 8 kHz Switching Frequency Factory setting 11 DRIVE OPERATION 11 1 START UP PROCEDURE After the drive has been properly setup jumpers and trimpots set to the desired positions and wiring...

Страница 17: ...generation Protection It is recommended that for very high inertial loads that both the ACCEL and DECEL Trimpots be set to greater than 10 seconds 12 5 DC INJECTION BRAKE TRIMPOT DECEL The drive is fa...

Страница 18: ...which provides indication of a fault or abnormal condition The information provided can be used to diagnose an installation problem such as incorrect input voltage overload condition and drive output...

Страница 19: ...ge Volts DC 0 to 2 5 thru 0 to 25 0 to 5 Signal Offset Trimpot OFFSET Range of SCALE Trimpot Setting 0 40 0 Input Current Range mA DC 4 20 Forward and Reverse Input Switch Types Dry Contact or Open Co...

Страница 20: ...ve for a specific application 14 2 1 SCALE TRIMPOT SCALE The SCALE Trimpot is factory set to run the motor at full speed with a 10 Volt DC analog signal input For a higher analog signal input 25 Volt...

Страница 21: ...ASD SERIES INSTALLATION AND OPERATION MANUAL 21 NOTES...

Страница 22: ...ASD SERIES INSTALLATION AND OPERATION MANUAL 22 NOTES...

Страница 23: ...ASD SERIES INSTALLATION AND OPERATION MANUAL 23 NOTES...

Страница 24: ...uding injury to any person caused by items of our manufacture or sale Some states do not allow certain exclusions or limitations found in this warranty and therefore they may not apply to you In any e...

Отзывы: