background image

ASD SERIES INSTALLATION AND OPERATION MANUAL 

 INTRODUCTION 

Thank  you  for  purchasing  the  ASD  Adjustable  Frequency  Drive.  Acme  Engineering  &  Mfg.  Corp.  is  committed  to  providing  total  customer 
satisfaction  by  producing  quality  products  that  are  easy  to  install  and  operate.  The  ASD  is  manufactured  with  surface  mount  components 
incorporating advanced circuitry and technology. 
 
The drives are variable speed controls housed in a rugged NEMA 4X / IP65 washdown and watertight die-cast aluminum enclosure. They are 
designed to operate 208 

– 230 and 400/460 Volt 50 & 60 Hz 3-phase AC induction motors from subfractional thru 10 HP. The sine wave coded 

Pulse Width Modulated (PWM) output operates at a carrier frequency of 16 kHz which provides high motor efficiency and low noise. Adjustable 
Linear Acceleration and Deceleration are provided, making the drive suitable for 
soft-start applications. 
 
Due to its user-friendly design, the ASD AC drive is easy to install and operate. Tailoring to specific applications is accomplished with selectable 
jumpers and trimpots, which eliminate the computer-like programming required on other drives. However, for most applications no adjustments 
are necessary. 
 
Main features  include  adjustable RMS  Current  Limit  and  I

2

t  Motor Overload  Protection  (UL  approved  as  an  electronic  overload  protector for 

motors). In addition, Adjustable Slip Compensation with Static Auto-Tune and Boost provides high torque and excellent load regulation over a 
wide speed range. Power Start™ delivers over 200% motor torque to ensure start-up of high frictional loads. Electronic Inrush Current Limit 
(EICL™) eliminates harmful AC Line inrush current. A Run/Fault Relay is provided, which can be used to turn equipment on or off, to signal a 
warning if the drive is put into the Stop Mode, or if a fault has occurred. The drive is suitable for machine or variable torque (HVAC) applications. 
A jumper is provided for selection of Regenerative or DC Injection Braking. The drive includes a signal isolator. 
 
Standard  front  panel features  include  Diagnostic  LEDs  for  "Power  On"  and  "Drive  Status"  and  a  Main Speed  Potentiometer.  Other features 
include a Barrier Terminal Block to facilitate wiring of the AC Line and motor, adjustable trimpots (MIN, MAX, ACCEL, DECEL, COMP, CL, JOG, 
BOOST), customer selectable jumpers (Line Voltage (dual voltage models only)), Motor Horsepower, Automatic Ride-Through / Manual Start, 
Motor  Frequency,  Frequency  Multiplier,  Fixed/Adjustable  Boost,  Regenerative  /  Injection  Braking,  "Run"  or  "Fault"  Output  Relay  Operation, 
NO/NC Stop Contact, Constant/Variable Torque, Switching Frequency, and GFCI operation). 
 

4.1 

– STANDARD FEATURES 

Industrial Duty Die-Cast Aluminum Case with Hinged Cover:

 Available in dark gray finish or FDA approved white finish. 

 

Simple to Operate:

 Does not require programming. Uses trimpots and jumpers, which are factory set for most applications. 

 

Motor HP Selection Jumper (J2):

 Allows the drive to be used on a wide range of motors without recalibration. 

 

Switching Frequency and GFCI Selection Jumper (J12):

 Allows the drive to be operated at 8 kHz or 12 kHz and on Standard (G1) or Sensitive 

(G2) GFCIs. 

 

Diagnostic LEDs:

 Power on (POWER) and drive status (STATUS). 

 

Run/Fault Relay Output Contacts:

 Can be used to turn equipment on or off, to signal a warning if the drive is put into the Stop Mode, or a fault 

has occurred. 

 

Barrier Terminal Block:

 Facilitates wiring of motor, AC Line, and Run/Fault Relay Output Contacts. 

 

Jumper Selection of Drive Output Frequency:

 Increases the motor speed up to two times the rated RPM. 

 

Ride-Through:

 Provides smooth recovery to the previous set speed during a momentary power loss (of less than 2 seconds). 

 

Holding Torque at Zero Speed: 

Resists motor shaft rotation when the drive is in Stop Mode. 

 

Adjustable  Trimpots: 

Maximum  Speed  (MAX),  Minimum  Speed  (MIN),  Acceleration  (ACCEL),  Deceleration  (DECEL),  DC  Injection  Brake 

(DECEL), Boost (BOOST), Current Limit (CL), Jog (JOG), Slip Compensation (COMP).  

 

Selectable Jumpers: 

AC Line Input Voltage (J1 

– ASD-24D, 27D only), Motor Horsepower (J2), Automatic Ride-Through or Manual Start (J3), 

Frequency Multiplier (J4), Motor Frequency (J5), Fixed or Adjustable Boost (J6), Regeneration or DC Injection Braking (J7), "Run" or "Fault" 
Output Relay Operation (J8), Normally Open or Closed Stop Contact (J9), Constant or Variable Torque (J10), Switching Frequency and GFCI 
(J12). 

 

Signal Isolator: 

Provides an isolated interface between non-isolated signal sources and the drive. See Section 14 on page 18. 

 

 

4.2 

– PEERFORMANCE FEATURES 

Power 

Start™:

 Provides more than 200% starting torque which ensures startup of high frictional loads. 

 

Slip Compensation with Static Auto-Tune and Boost:

 Provides excellent load regulation over a wide speed range. 

 

Speed Range:

 60:1. 

 
 

4.3 

– PROTECTION FEATURES 

Motor Overload (I

2

t) with RMS Current Limit:

 Provides motor overload protection which prevents motor burnout and eliminates nuisance trips. 

UL approved as an electronic overload protector for motors. 

 

Electronic Inrush Current Limit (EICL™):

 Eliminates harmful Inrush AC Line current during startup. 

 

Short Circuit:

 Shuts down the drive if a short circuit occurs at the motor (phase-to-phase). 

 

Regeneration:

 Eliminates tripping due to high bus voltage caused by rapid deceleration of high inertial loads. 

 

Undervoltage and Overvoltage:

 Shuts down the drive if the AC Line input voltage goes above or below the operating range. 

 

MOV Input Transient Suppression:

 Protects the drive components against damaging voltage spikes on the AC Line. 

 

Microcontroller Self-Monitoring and Auto Reboot. 

Содержание ACME SYNC ASD Series

Страница 1: ...TE The drive is factory set for 60 Hz motors For 50 Hz motors see Section 10 4 on page 15 See Safety Warnings on page 5 LISTED IND CONT EQ 70ZA 3 RoHS This Manual Covers Models ASD 24D 27D 29 29 1P 45...

Страница 2: ...Hz Motor Operation 15 10 4 2 Setting the Drive for Two Times the Rated Motor RPM 15 10 5 Boost Mode Selection J6 16 10 6 Braking Mode Selection J7 16 10 7 Run Fault Output Relay Operation Selection J...

Страница 3: ...oost Mode Selection J6 16 19 Braking Mode Selection J7 16 20 Run Fault Output Relay Operation Selection J8 16 21 Stop Contact Type Selection J9 16 22 Torque Mode Selection J10 16 23 Switching Frequenc...

Страница 4: ...lt AC Line input and 2 HP maximum with 208 230 Volt AC Line input ASD 29 Designed to accept 1 phase Terminals L1 L2 or 3 phase Terminals L1 L2 L3 AC Line input Rated for 208 230 Volt AC Line input onl...

Страница 5: ...tilated 3 phase AC induction motors will overheat if used beyond a limited speed range at full torque Therefore it is necessary to reduce motor load as speed is decreased Note Some fan cooled motors c...

Страница 6: ...rial Duty Die Cast Aluminum Case with Hinged Cover Available in dark gray finish or FDA approved white finish Simple to Operate Does not require programming Uses trimpots and jumpers which are factory...

Страница 7: ...put Voltage Operating Range Volts AC 208 15 230 15 400 460 Volt AC Line Input Voltage Operating Range Volts AC 380 15 460 15 Maximum Load Current Overload for 2 Minutes 150 Switching Frequency kHz Jum...

Страница 8: ...on See Section 10 2 on page 15 5 Jumper J5 Motor Frequency selection See Section 10 4 on page 19 6 Jumper J12 Switching Frequency and GFCI selection See Section 10 11 on page 16 7 Jumper J6 Adjustable...

Страница 9: ...ee Section 10 5 on page 16 5 Jumper J4 Frequency Multiplier selection See Section 10 4 on page 15 6 Jumper J7 Regeneration or DC Injection Braking See Section 10 6 on page 16 7 Jumper J5 Motor Frequen...

Страница 10: ...15 4 Jumper J6 Adjustable Boost selection See Section 10 5 on page 16 5 Jumper J4 Frequency Multiplier selection See Section 10 4 on page 15 6 Jumper J7 Regeneration or DC Injection Braking See Sectio...

Страница 11: ...should be taken to avoid extreme hazardous locations where physical damage can occur When mounting the drive in an enclosure the enclosure should be large enough to allow for proper heat dissipation s...

Страница 12: ...ASD SERIES INSTALLATION AND OPERATION MANUAL 12 FIGURE 8 ASD 27D 29 29 1P 45 48 MECHANICAL SPECIFICATIONS Inches mm Tighten these screws in the sequence shown to 12 in lbs 14 kg cm...

Страница 13: ...gasket is slightly compressed The recommended tightening torque is 12 in lbs 14 kg cm do not overtighten See Figures 7 and 8 on pages 11 and 12 for the tightening sequence Application Note To avoid e...

Страница 14: ...G All equipment AC Line inputs must be disconnected from the AC power Connect all equipment AC power input lines together and connect them to the H V lead of the hi pot tester Connect the RETURN lead...

Страница 15: ...ut 10 3 AUTOMATIC RIDE THROUGH OR MANUAL START SELECTION J3 Jumper J3 is factory set to the A or AUTO position for Automatic Ride Through If the power is interrupted for up to 2 seconds the drive will...

Страница 16: ...ing Frequency 8 kHz Switching Frequency Factory setting 11 DRIVE OPERATION 11 1 START UP PROCEDURE After the drive has been properly setup jumpers and trimpots set to the desired positions and wiring...

Страница 17: ...generation Protection It is recommended that for very high inertial loads that both the ACCEL and DECEL Trimpots be set to greater than 10 seconds 12 5 DC INJECTION BRAKE TRIMPOT DECEL The drive is fa...

Страница 18: ...which provides indication of a fault or abnormal condition The information provided can be used to diagnose an installation problem such as incorrect input voltage overload condition and drive output...

Страница 19: ...ge Volts DC 0 to 2 5 thru 0 to 25 0 to 5 Signal Offset Trimpot OFFSET Range of SCALE Trimpot Setting 0 40 0 Input Current Range mA DC 4 20 Forward and Reverse Input Switch Types Dry Contact or Open Co...

Страница 20: ...ve for a specific application 14 2 1 SCALE TRIMPOT SCALE The SCALE Trimpot is factory set to run the motor at full speed with a 10 Volt DC analog signal input For a higher analog signal input 25 Volt...

Страница 21: ...ASD SERIES INSTALLATION AND OPERATION MANUAL 21 NOTES...

Страница 22: ...ASD SERIES INSTALLATION AND OPERATION MANUAL 22 NOTES...

Страница 23: ...ASD SERIES INSTALLATION AND OPERATION MANUAL 23 NOTES...

Страница 24: ...uding injury to any person caused by items of our manufacture or sale Some states do not allow certain exclusions or limitations found in this warranty and therefore they may not apply to you In any e...

Отзывы: