5. Preset / Reset Multi-Register (Function Code 16)
Query
Function 16 allows the user to modify the contents of a multi-register. Any register
that exists within the meter can have its contents changed by this message. The
example below is a request to meter number 1 to preset alarming value(1000),
alarming delay(4s), and alarming output to RO1.
Addr
Fun
Data start
reg HI
Data start
reg LO
Data # of
reg HI
Data # of
reg LO
Byte Count
01H
10H
01H
0BH
00H
03H
06H
Value1
HI
Value1
LO
Value2
HI
Value2
LO
Value3
HI
Value3
LO
CRC
HI
CRC
LO
07H
D0H
00H
05H
00H
01H
82H
3DH
Response
The normal response to a preset multi-register request includes the slave address,
function code, data start register, the number of registers and error checking.
Table 4.12 Preset / Reset Multi-Register Message