[61] wAppLoxx Pro Control Plus Complete
Instructions
V5
Alarm input
An alarm is signalled via the alarm input for the wAppLoxx Pro Control Plus.
Input 3 is used by default (see Chapter 3).
Activity signal
You can use the “Activity signal” option to change the input processing method.
▪
High: If 12 V are applied at the input, the alarm status is active.
▪
High: If 0 V are applied at the input, the alarm status is not active.
▪
Low: If 0 V are applied at the input, the alarm status is active.
▪
Low: If 12 V are applied at the input, the alarm status is not active.
Status
The current status of the input is displayed.
Connection to the alarm panel
There are four options for connecting the wAppLoxx Pro Control Plus to an alarm panel:
1. Alarm system fully wired
The Arm Input, Arm Output and Ready for Arm options are connected to the alarm panel.
This makes it possible to “arm” and “disarm” the system using the wAppLoxx Pro Control
Plus. Furthermore, the Arm command is only sent when forced action is required via the
Ready for Arm input. The Arm Input has the highest priority and also operates the wAppLoxx
Pro Control Plus at the same time.