If a wAppLoxx Pro Repeater or a wAppLoxx Pro Plus Slave Control should be
integrated into the master key system, it must be programmed first, as associated
wAppLoxx Pro components must be assigned to a slave control/repeater during
programming.
Programming a wAppLoxx Pro Cylinder
1.
Click "Register device"
2.
Present the “system card” at the cylinder. Green flashing will indicate the start of the
learning process.
3.
The cylinder will now connect to the wAppLoxx Control Pro Plus or to the wAppLoxx
Pro Repeater. This process may take a few seconds.
4.
After successfully programming, the hardware ID of the cylinder will be displayed.
Walk test
To carry out a walk test, activate the Walk Test.
You will now be
prompted to turn the relevant wAppLoxx Pro cylinder knob. While
you are doing so, you will be able to see the cylinder’s signal
strength in the software. The signal strength of a bridge box will
be displayed during the walk test by pressing the cover contact
button (see illustration). The walk test is used to assess
the cylinder’s wireless communication; special
equipment is required for more precise radio
measurements. The following table shows the results of
the walk test.
Walk test grades
No bar:
Installation not possible.
1 bar:
Weak reception that can be lost due to minor disturbances or
influences. Installation is not recommended.
2 bars:
Good reception, installation can be done with little risk.
3 bars:
Strong reception, installation can be carried out with very little risk of
radio failure.
Office mode
Cylinders that have Office mode activated allow the door to be opened without a tag by
turning the cylinder knob. To restrict Office mode to a certain time frame, you can assign the
relevant wAppLoxx Pro Cylinder to a self-defined schedule.