Commissioning 

 

 

25 

 

Commissioning

 

Initial commissioning/factory reset 

 

Note 

The wireless alarm system 

cannot

 be accessed 

via the web server without running the 
installation/start wizard. 

1.  Connect your PC to your customer's network. 

 

2.  Switch on the power supply. 

3.  Follow the installation/start wizard on the alarm panel. 

4.  Select: 

 

the language 

 

the country-specific settings 

 

a 4 or 6-digit user code 

 

the type of wired zone  
(e.g. 2-wire FSL 2K2/4K7). 

5.  The overview then displays: 

 

the IP address of the wireless alarm system 

 

DHCP ON/OFF 

 

the current software version 

 

the serial number of the wireless alarm system 

 

the part number of the wireless alarm system 

 

the temporary login data for the installer and 
administrator. 

6.  Make a note of the IP address. 

7.  Open the web browser on your PC and enter the 

IP address indicated by the alarm panel. 
Alternatively you can also use the ABUS IP Installer 
to display the alarm panel and automatically access 
it. You can download the IP Installer from 

www.abus.com

.  

8.  Connect to the wireless alarm system via the web 

browser. 

 

Note 

When the alarm panel is first set up, it may take 
up to three minutes for the web browser to access 
the wireless alarm system as the SSL certificate is 
automatically generated during this time. 

9.  Log into the wireless alarm system as an installer. 

 

Note 

It is sometimes beneficial to use a fixed 
IP address instead of a dynamically assigned 
IP address (DHCP). 

Some routers assign other IP addresses to their 
clients after a certain time, for example. Other 
devices do not recognise this new IP address yet. 

For a system that is already installed 

1.  Log into the wireless alarm system as an installer. 

2.  Navigate to the following submenu: 

Info>Communications>Ethernet.  

3.  Make a note of the IP address. 

4.  Log out of the alarm panel. 

5.  Open the web browser on your PC and enter the 

IP address indicated by the alarm panel. 

6.  Open the web browser on your PC and enter the 

IP address indicated by the alarm panel. 

7.  Enter your user name and password to log onto 

the web server. 

Содержание SECVEST

Страница 1: ...I n s t a l l e r m a n u a l...

Страница 2: ...aanduiding van de paginanummers English Dansk These user manual contains important information for installation and operation This should be also noted when this product is passed on to a third party...

Страница 3: ...Contents 3...

Страница 4: ...23 Positioning the wireless alarm system alarm panel 23 Fixing the mounting plate 23 Connecting the components 24 Installing the optional GSM FUMO50000 24 Installing the micro SD card 24 Final steps...

Страница 5: ...116 ARC Reporting CID SIA Events for all protocols EXCEPT Fast Format 117 ARC Reporting More 118 Social Care 121 Social Care Phone Book 123 Social Care Account Numbers 124 Speech Dialler 125 Speech Di...

Страница 6: ...Contents 6 VoIP error messages 160 Time zones 161 Landline notification centre 161 GSM network notification centre 162 SMS notification 162 Email notification email setup 163 Index 167...

Страница 7: ...menus Installing Secvest The installation of the Secvest wireless alarm system is described in chapter Mounting Installation from page 21 Additional information can be found in the document supplied...

Страница 8: ...use of electronic devices Caution All guarantee claims are invalid in the event of damage caused by non compliance with these instructions We cannot be held liable for resulting damage Caution In the...

Страница 9: ...on The alarm panel is supplied power via an integrated power supply unit The power supply unitis connected to the building s 230 V AC grid via a separately secured line Connection to the building s gr...

Страница 10: ...device cannot be tampered with when the alarm panel is mounted The alarm panel should be mounted at a comfortable height between 1 5 and 2 m Note If small children are present the alarm panel should b...

Страница 11: ...e armed 2 Confirmation buttons Used to navigate to a higher lower menu level or to select options or to exit a menu 6 Disarm button Monitoring is deactivated device disarmed 3 Navigation buttons Used...

Страница 12: ...Device overview 12 International key assignment...

Страница 13: ...tamper switch 9 Connection for mains voltage 110 V 230 V AC 50 60 Hz 3 Code reset PINs 10 Micro SD card holder 4 Connection for optional GSM module FUMO50000 11 Fuse holder for mains fuse 5 Connection...

Страница 14: ...Device overview 14...

Страница 15: ...tectors but also monitor attempts to open a door or window using a lever via innovative magnetic field sensors Perimeter protection All points of access to the premises are monitored including house d...

Страница 16: ...ter name on the IP network such as example org The user sends this domain as the query The URL is then converted by the DNS into the associated IP address the connection number on the IP network e g a...

Страница 17: ...ed for telephony but also for line and packet based data transmission and short text messages SMS HTTPS HyperText Transfer Protocol Secure a communications protocol on the web used to transfer data se...

Страница 18: ...edical emergency Personal medical emergency for which help can be arranged using an alarm NC Normally Closed contact or switch that opens when actuated NO Normally Open contact or switch that closes w...

Страница 19: ...r the security field Signals from wireless earphones mobile phones garage door openers etc cannot interfere with devices operating in these ranges Europe frequency use specification of the European Co...

Страница 20: ...e This alarm does not trigger any sounders indoors and outdoors remains quiet and calm but an alarm receiving centre is discreetly notified intruder is not scared off rather caught in the act aggressi...

Страница 21: ...from an independent body that ensures the high quality and safety of alarm systems in Germany the following are relevant certification as per POS in accordance with accident prevention regulations and...

Страница 22: ...m signalling device Open drain transistor output 500 mA 13 8 V DC 3 Z303 Z304 wired zones 303 and 304 8 TR tamper return tamper input from a wired sounder 4 Z301 Z302 wired zones 301 and 302 9 TRB tro...

Страница 23: ...it is armed The alarm panel should be mounted near a socket or power supply If a telephone dialler is used the alarm panel must be connected to a telephone connection The alarm panel should be mounted...

Страница 24: ...labelled precisely when the system is installed 11 Connect all components to the terminal blocks 12 Ensure that all connections are securely fitted Installing the optional GSM FUMO50000 If available...

Страница 25: ...el and automatically access it You can download the IP Installer from www abus com 8 Connect to the wireless alarm system via the web browser Note When the alarm panel is first set up it may take up t...

Страница 26: ...to the wireless alarm system it cannot be accessed via web browser for security reasons Note Depending on the browser a message may appear indicating that the connection certificate is unsafe Confirm...

Страница 27: ...tputs 57 Wired Outputs 58 Partitions 68 Configure partitions Full Set 69 Configure partitions Part Set 76 Configure partitions HUA response 84 System 86 General 86 Installer Details 90 User Access 91...

Страница 28: ......

Страница 29: ...main menus are displayed 2 Button for online help Click this button to open the current documentation as a PDF This documentation can then be saved locally as well 5 Submenu list The submenus associa...

Страница 30: ...d for the user name Enter 999999 or 9999 The entry is case sensitive 3 Login button 2 Input field for the password Enter 999999 or 9999 as an installer The entry is case sensitive Note You are automat...

Страница 31: ...ation about the status of the alarm system partitions 37 5 Partitions Overview configuration of the partitions 69 3 Devices Overview configuration of the components IP zones Wireless Zones Wired Zones...

Страница 32: ...e Speech Dialler SMS Email Communication options Contacts 110 9 View Log Overview of faults events and processes on all components of the alarm system 152 8 Social Care Overview configuration of socia...

Страница 33: ...lanation Version Version number of the software currently installed on the alarm system Serial Number Serial number of the alarm system Part No Article number of the alarm system Language Set language...

Страница 34: ...ns PSTN Name function Explanation PSTN Link Status Queries the PSTN link status Secvest checks the connected telephone line The message OK appears If it is not connected not enabled or is disrupted th...

Страница 35: ...s the Secvest automatically obtains its IP address from a DHCP server for example in a router If the Secvest is not networked 0 0 0 0 is displayed here IP Subnet Mask The subnet mask is displayed here...

Страница 36: ...e offer Installer Code ID of the wireless alarm system required for the licence key Please enter code Input field for the licence key for customisation of the alarm system language settings for exampl...

Страница 37: ...arm that is confirmed by the user but not reset is displayed in the corresponding partition as a warning symbol Clicking this warning symbol resets this alarm 2 Status display The status display conta...

Страница 38: ...idual IP zone Attributes Overview of the attribute and status of the individual IP zone Note To integrate a network camera into a free IP zone it must first be integrated and configured in the alarm p...

Страница 39: ...larm panel Trigger Events for External or Int Ext trigger mode only Events which cause the camera to start recording Trigger Partitions for External or Int Ext trigger mode only Partitions to be monit...

Страница 40: ...me once the configuration is complete by selecting Submit Selecting the zone type Note The preset zone type can be changed here Note the description of the zone types in this section A zone is a detec...

Страница 41: ...A zone configured as Exit Norm Alm behaves similarly to a Normal Alarm zone A zone of this type however starts an alarm even when the detector is triggered during the exit time Hold Up Alarm This zon...

Страница 42: ...per switch of the housing If the housing is opened the wireless alarm panel saves the event and reports it to the alarm reception centre Tamper This zone is used for tamper monitoring of external devi...

Страница 43: ...activated and Ext PSU Batt Fault appears on the display If this fault is triggered while the system is armed a log book entry is created and the communication configured accordingly is started but no...

Страница 44: ...matically omitted if it was open when the system was armed Attribute Explanation Omittable If a zone is given this attribute a user can omit this zone before arming the system If a user attempts to ar...

Страница 45: ...function and do not activate the soak test as this function stops the detector from triggering any alarms when the wireless alarm system is armed and only saves a message to the memory instead After...

Страница 46: ...41 Adding deleting detectors alarm panel only 1 Select menu Devices Wireless Zones 2 The following function is available Function Explanation Add Del Detectors Select this item to view a list of all...

Страница 47: ...ready used may appear on the display when you are teaching in a detector after you have received confirmation of the teach in process because the detector sends its signal more than once In this case...

Страница 48: ...e of the zone Partition Partition of the individual zone Type Type of the individual wired zone Attributes Overview of the attributes for the individual wired zone Delete All alarm panel only 1 Select...

Страница 49: ...Configuration 49 Note The description of the configuration of the zone name partition zone type and zone attributes can be found after the IP zones overview from page 41...

Страница 50: ...alarm panel only Note Up to eight wireless control devices can be taught in 1 Select Add Del Ctrl Device 2 Select the corresponding control device 3 Trigger the tamper contact of the control device se...

Страница 51: ...to be triggered when the button is pressed Not Used C button has no function Set Arm the assigned partitions Part Set Internally arm the assigned partitions Unset Disarm the assigned partitions Outpu...

Страница 52: ...ears on the display to confirm that the siren was added and the value for the received signal strength is shown 5 Exit the entry with Back Note If a siren has been taught in the symbol appears next to...

Страница 53: ...Configuration 53 Wired Sirens Name function Explanation Number The number comprises the component type Wired SRN and a consecutive number Name Unique name of the wired siren...

Страница 54: ...1 After selecting this menu item the following display appears Select Add Del Siren 2 Select the corresponding siren 3 After selecting this menu item the following display appears Is the receiver is...

Страница 55: ...4 217 220 245 WAM 5 213 216 244 WAM 6 209 212 243 WAM 7 205 208 242 WAM 8 201 204 241 Note Configure the wireless accessory module as describe in the WAM installation instructions e g as a wireless s...

Страница 56: ...se outputs no longer have to be added manually Simply define the settings for the output function as described in section Editing outputs These outputs only need to be configured but no longer have to...

Страница 57: ...amper contact of the door lock or insert a battery Note When the door lock has been taught in the wireless alarm panel beeps twice to confirm A message appears on the display to confirm that the door...

Страница 58: ...assign unique output names so that if a fault occurs it is easier to identify the affected output 2 Delete the preset name 3 Assign a unique name for the output with max 12 characters Inverting outpu...

Страница 59: ...ique output names so that if a fault occurs it is easier to identify the affected output 2 Delete the preset name 3 Assign a unique name for the output with max 12 characters 4 Confirm the selection o...

Страница 60: ...normal alarm The alarm panel activates the output when Two normal alarms are triggered in the same partition during the confirmation time A normal alarm and a tamper alarm are triggered in the same p...

Страница 61: ...de A duress code has been used The alarm panel activates the output as soon as a user enters a duress code and deactivates the output again when the user resets the system Yes Confirmed Alarm This out...

Страница 62: ...robe This output is activated when there is a local alarm in the selected partition and remains activated until the wireless alarm panel is disarmed The output is also activated for 10 seconds after t...

Страница 63: ...activated until all detectors no longer send this message Yes Battery Fault The output is activated when the alarm panel identifies a fault with the backup battery OR a zone with zone type Ext PSU Ba...

Страница 64: ...ated as soon as an event occurs that causes a fault This includes RF Low Battery RF Supervision RF Jamming A C Fault Battery Fault Ext PSU Fault Tamper Note that in the event of an A C Fault the outpu...

Страница 65: ...earmed after the siren time has expired In a system with partitions the output can be assigned to different partitions The output is deactivated again when a user or installer resets the system or the...

Страница 66: ...put The alarm panel restores the zone and resets the output when a user or installer resets the system Entry Exit Follow This output is activated for the duration of the delay time entry delay or exit...

Страница 67: ...lay time has expired Yes Installer on Site The output is activated as soon as the alarm panel is in installer mode and deactivated as soon as the installer has successfully exited this menu No Walk Te...

Страница 68: ...ed when the system or partition is disarmed or an alarm event occurs The output is activated for one second when either the system is reset or installer mode is exited on the alarm panel Note if Norma...

Страница 69: ...ed partitions appear in the Full set link line Full set link Use this option to define a common partition Partition 1 is always the common partition Partition 1 can be connected linked to other partit...

Страница 70: ...cters are allowed The alarm panel displays this name during arming Full Set Settings for the complete arming of the partition Exit Mode Select the mode of arming when exiting the premises Timed Set Us...

Страница 71: ...exit time has expired Under Exit time select the corresponding time However no warning tone sounds during this time If the partition has been armed an acoustic confirmation sounds The alarm panel sav...

Страница 72: ...ng area The user can start the arming sequence using the user code proximity keyfob or remote control Note arming with remote control must not be set to Instant Installer Mode System User Access Remot...

Страница 73: ...d 120 s Alarm Response Select the response here for when an alarm occurs in this partition Internal Alarm panel indoor siren info module and control device Siren Alarm panel indoor siren info module a...

Страница 74: ...s one visual acknowledgement on the wireless external siren Strobe outputs are activated for 10 s after successfully arming the partition Off After successfully arming the partition there is no visual...

Страница 75: ...minutes after a burglar alarm The siren time can be set to a value between 0 and 20 min If sounders are assigned to multiple partitions the alarm panel uses the longest siren time set for the partiti...

Страница 76: ...ted an intrusion during your absence The delay time runs anyway Disarm the alarm panel within the delay time Do so only if you feel it is safe however An intruder could still be inside the property If...

Страница 77: ...ed The alarm panel displays this name during arming Part Set Settings for the internal arming of the partition Exit Mode Select the mode of internal arming when exiting the premises Timed Set Use this...

Страница 78: ...still be locked During this time it cannot send signals to complete the arming process Instant Set The partition is internally armed immediately without any acoustic warning tone If the partition has...

Страница 79: ...Door zone The entry time starts when the door is opened The entry tone sounding at this point is different from a normal entry tone If the user locks the door again without starting the entry time th...

Страница 80: ...rm signal and have still not been reset During this time the alarm panel ignores alarm signals from detectors and sirens are not triggered Enter the time in seconds as a 2 digit number 01 30 The facto...

Страница 81: ...ons the alarm panel uses the shortest siren delay set for the partitions in question Siren time ext min Time for the duration of the external siren s in minutes The siren time can be set to a value be...

Страница 82: ...successfully internally arming the partition there is one visual acknowledgement on the wireless external siren Strobe outputs are activated for 10 s after successfully arming the partition Off After...

Страница 83: ...ternal siren s in minutes after a burglar alarm The siren time can be set to a value between 0 and 20 min If sounders are assigned to multiple partitions the alarm panel uses the longest siren time se...

Страница 84: ...ed an intrusion during your absence The delay time runs anyway Disarm the alarm panel within the delay time Do so only if you feel it is safe however An intruder could still be inside the property If...

Страница 85: ...nd the connected sirens according to the set siren time A triangle warning appears on the alarm panel display to indicate the hold up alarm Details are displayed after a user code is entered The acous...

Страница 86: ...unders and the connected sirens according to the set siren time The hold up alarm and details are shown on the alarm panel display No user code must be entered to view the details The acoustic warning...

Страница 87: ...Text Name max 20 characters shown on the Secvest display Restore Defaults Only available on the alarm panel This menu item resets the device back to its factory defaults After confirmation the followi...

Страница 88: ...not change the selected language Access Code Length 4 Digit User Codes 6 Digit User Codes Wired Zone Type 2 wire FSL 2K2 4K7 2 wire FSL 1K 1K 2 wire FSL 2K 2K 2 wire FSL 4K7 4K7 4 wire CC 2 wire CC O...

Страница 89: ...a log book entry is created Power supply restored If the power disruption lasts longer than 9 s the following occurs If the value is set to 0 min a warning tone is sounded after 10 s and the alarm pa...

Страница 90: ...s set to 0 min a warning tone is sounded after 10 s and the alarm panel reports the failure DC Fault outputs are activated If the value is set to higher than 0 min this timer is started 10 s after the...

Страница 91: ...er access code on the alarm panel Factory Defaults 9999 4 digit user code 999999 6 digit user code It is a good idea to change this code The installer code can be used to access installer mode and per...

Страница 92: ...re alarm hold up alarm medical alarm on the alarm system or control device Deactivated Function not possible Social Care Key Activated Manual triggering of a social care alarm is possible by simultane...

Страница 93: ...y has access to the system when a user is present Activated After the installer has entered their code the system prompts the user to enter their user code Only once a user code has also been entered...

Страница 94: ...ting a Duress Code User The system can be armed or disarmed using a duress code Important If a user is forced by an intruder to disarm the alarm system they should disarm the system using a duress cod...

Страница 95: ...larms Activated Allows the user to reset this alarm triggered for zones or detectors Deactivated User cannot perform a reset The installer must reset the system after an alarm Zone Tampers Activated A...

Страница 96: ...m a reset The installer must reset the system This setting is required for INCERT certification System tampers can be caused by Housing and wall tamper switches on the alarm panel Housing and wall tam...

Страница 97: ...s configured to Unconfirm Siren On Dropdown selection field for Unconfirm Confirm Note Confirm can only be selected if Sounder On is configured to Unconfirm Confirmation Time Confirmation Mode DD243 a...

Страница 98: ...nce door has been opened relevant for DD234 Unconfirmed Reset Confirmation Mode DD243 and BS8243 only Dropdown selection field for Installer User After Entry Confirmation Mode DD243 and BS8243 only Dr...

Страница 99: ...iren responds to fire alarms burglar alarms and hold up alarms Siren Strobe The wireless siren operates the siren and strobe when an alarm is triggered Strobe The wireless siren operates only the stro...

Страница 100: ...erly The SD card can then be safely removed Enable Hardware After insertion the SD card is brought into operation again Read and write operations can run again GSM antenna The menu only appears when a...

Страница 101: ...its When switching from 4 to 6 digit numerical codes 00 is automatically added to the end of the existing 4 digit codes Example 1234 becomes 123400 Switching from 6 to 4 digits When switching from 6 t...

Страница 102: ...og book entry of this event No display and no warning tones RF Supervision or RF Fault outputs are activated Log book entry of this event Display and warning tones RF Supervision or RF Fault outputs a...

Страница 103: ...are also activated If no tamper channel is assigned in FF an unconfirmed alarm is sent Tamper alarm Jamming is reported Note If Tamp as Tamp Only is disabled the Jamming or Fault outputs are also act...

Страница 104: ...e button on the remote control again to confirm that the system should arm On The user only has to press the corresponding button on the remote control once to start the arming process Note With the C...

Страница 105: ...en started beforehand Final Door zone is triggered Dropdown selection field for Always The user can always disarm the possible partitions without the entry time being started first During entry time T...

Страница 106: ...ute Silence Alerts silent warnings This option controls the length of time in which warning tones a brief beep every few minutes are sounded Dropdown selection field for User Code Warnings are sounded...

Страница 107: ...s the user can reset the system This setting is compliant with EN 50131 Deactivated No additional delay when deviating from the entry route An alarm is immediately triggered if a user deviates from t...

Страница 108: ...ration to be restored Click the Load Configuration button to import the configuration to be restored into the wireless alarm system The wireless alarm system must then be restarted Backup Click the Ba...

Страница 109: ...uage file to be loaded Click the Submit button to import the selected file into the wireless alarm system Application File Click the Browse button to specify the path and file name of the application...

Страница 110: ...Address Gateway IP address DNS Primary IP Address DNS primary IP address ABUS Server Enabled Activated Establishes a connection to the ABUS server An account for Secvest must be created Deactivated F...

Страница 111: ...provider either the entire email address or a separate user name Password Password for the email account Note This entry is case sensitive SSL Activated An encrypted connection SSL to the provider is...

Страница 112: ...r Password SIP user password of the SIP service provider SIP Port Port of the SIP service provider RTP Port RTP port number SIP Test Call Dest User ID User ID for a test call via SIP SIP Dialler Enabl...

Страница 113: ...rting Name function Explanation checkbox Call Mode Dropdown selection field for Disabled Single Alternate Protocol Dropdown selection field for Fast Format Contact ID SIA 1 SIA 2 SC SIA 3 Ex SIA 3 Ex...

Страница 114: ...Configuration 114 ARC Reporting Phone Book Name function Explanation checkbox Tel Recipient Name of the recipient...

Страница 115: ...ID account number up to 6 digits for the partition in question CID uses 4 digit account numbers With Fast Format you can use four five or six digit account numbers The alarm panel adds a leading zero...

Страница 116: ...urglar Alarm P4 HU Alarm HUA Confirm Duress Code Confirmed Alarm Fire Alarm Technical Alarm Alarm Abort Medical Alarm Key Box Tamper RF Supervision RF Jamming RF Low Battery Mains Fault General Fault...

Страница 117: ...larm Technical Alarm Set Unset Reset Omit RF Supervision RF Battery PSU Mains Fault Installer Mode Time Date Reset HU Alarm Burglar Alarm Tampers Part Set Exit Timeout Key Box RF Jamming Panel Battery...

Страница 118: ...to the ARC two bits of information are transmitted to the ARC Type and time of the event taking place Event reset The event reset is called a restoral Activated The information about the event reset...

Страница 119: ...the status messages are not transmitted to the ARC Burg Comms Rearm Appears only when the following is set System Confirmation Confirmation Mode Basic and Communications Protocol Fast Format Activated...

Страница 120: ...THE HOUR For Static Test Call only Daily Weekly Monthly Input field for the time of the daily test call hh mm SET THE DAY For Static Test Call only Weekly Dropdown selection field for Sunday Monday T...

Страница 121: ...ods should be used here PSTN 1 2 or No GSM 1 2 or No 21CN Ack Time An analogue telephone connection to the ARC directed via the new public telephone networks sometimes takes more time than a conventio...

Страница 122: ...e Activated A social care alarm transmission must be confirmed by the recipient by pressing DTMF button 5 otherwise the calls will be repeated Deactivated If the function is deactivated the emergency...

Страница 123: ...hone Book Name function Explanation checkbox Tel Recipients 1 to 2 After clicking in the selection field a pop up window appears where the desired telephone number of a recipient can be selected from...

Страница 124: ...Care Account Numbers Name function Explanation checkbox Account No P Store an 8 digit account number factory default 00000000 for switching to a social care alarm centre or alarm receiving centre for...

Страница 125: ...re Ethernet 1 2 3 or No PSTN 1 2 3 or No GSM 1 2 3 or No Call Acknowledge Activated The alarm transmission must be confirmed by the recipient with 5 or 9 Pressing DTMF button 5 calls to this number ar...

Страница 126: ...Triggers Name function Explanation checkbox Trigger Dropdown selection field for None Burglar Alarm Hold Up Alarm Fire Alarm Medical Alarm Social Care Alarm Social Inactivity Technical Alarm Soak Test...

Страница 127: ...Destinations Name function Explanation checkbox Recipient After clicking in the selection field a pop up window appears where the desired telephone number or SIP ID of a recipient can be selected fro...

Страница 128: ...Explanation checkbox Enabled Activated The SMS function is available Deactivated The SMS function is not available Telecoms Priority Set the order in which the communication methods should be used he...

Страница 129: ...129 SMS Triggers Name function Explanation checkbox Message After clicking in a selection field a pop up window appears where the desired trigger for message 1 to 4 can be selected Tampers Alarms Sets...

Страница 130: ...Destinations Name function Explanation checkbox Message After clicking in the selection field a pop up window appears where the desired telephone number of a recipient can be selected from the contac...

Страница 131: ...Configuration 131 SMS Destinations Message Name function Explanation checkbox Tel Recipient Selection of recipient 1 to 8 for message 1 to 4...

Страница 132: ...Configuration 132 SMS Destinations Message Telephone Recipients Name function Explanation checkbox None Do not select any recipients Recipient Select contact data for recipient A to L...

Страница 133: ...Configuration 133 SMS Messages Name function Explanation checkbox Home Message Store a home message max 30 characters Message Store message 1 to 4 max 30 characters...

Страница 134: ...any landline telephone connections The connection must be enabled for this however and all telecommunications equipment connected between the end of line and first TAE socket and the wireless alarm pa...

Страница 135: ...SMS notifications Note To send SMS messages from the GSM network starting from the GSM module the number of the SMS service centre for the network operator in question is already stored on the SIM car...

Страница 136: ...ction Explanation checkbox Enabled Activated The email function is available Deactivated The email function is not available Telecoms Priority Set the order in which the communication methods should b...

Страница 137: ...37 Email Triggers Name function Explanation checkbox Message After clicking in a selection field a pop up window appears where the desired trigger for message 1 to 4 can be selected Tampers Alarms Set...

Страница 138: ...ail Destinations Name function Explanation checkbox Message After clicking in the selection field a pop up window appears where the desired email address of a recipient can be selected from the contac...

Страница 139: ...Configuration 139 Email Messages Name function Explanation checkbox Home Message Store a home message max 30 characters Message Store message 1 to 4 max 30 characters...

Страница 140: ...the telephone connection Disabled Audible Silent GSM Line Fault Response only when GSM module is used Select how Secvest responds if a fault occurs with the GSM connection Disabled Audible Silent Call...

Страница 141: ...the private branch exchange or in the instructions of the private branch exchange It is usually the number 0 in the UK it is usually the number 9 Format of the telephone number 0 0123 4567890 The ala...

Страница 142: ...m panel answers a call 3 rings 5 rings 7 rings 10 rings 15 rings 255 rings Note If the value is set to 255 the alarm panel never answers the call Answer on 1 ring only when Call in control is activate...

Страница 143: ...Configuration 143 Contacts Up to 12 recipients can be defined here to whom messages are sent...

Страница 144: ...function Explanation checkbox Start Monitoring Hr Start time of social care monitoring hh mm End Monitoring Hr End time of social care monitoring hh mm Monitoring Interval Interval in hours Language V...

Страница 145: ...Once the partitions are selected only the detectors in the selected partitions are displayed Zones Selected detectors can be tested here A list of all detectors appears Select the detectors to be tes...

Страница 146: ...ency or social care alarm at the same time to test them On the display F dual keys fire alarm P dual keys hold up M dual keys medical emergency H dual keys social care alarm The lower and button on th...

Страница 147: ...rded signal strengths for the selected component Detectors The display shows the signal strength of each taught in detector The zone names are displayed To view the zone numbers press the right menu k...

Страница 148: ...ton open lock which user is assigned to this remote control the function of the pressed button F Set All Prt Set All or Output On Off or Toggle xyz Query Status Unset All the received signal strength...

Страница 149: ...ed contact Press the Select button The alarm panel sends a test call to this recipient The event or trigger Test is sent according to the set protocol During the test call a series of progress message...

Страница 150: ...his is selected enter a number to dial Press the OK button The alarm panel sends an SMS to this number The recipient receives an SMS in the following form Home Message 10 56 21 01 2015 SMS Test Call D...

Страница 151: ...the tamper loop S Example for a 2 wire FSL 2K2 4K7 zone Alarm contact closed standby 2k18 Alarm contact open 6k89 Alarm contact open and series resistor bridged 4k68 Short circuit in line to detector...

Страница 152: ...all of the relevant data for the alarm panel including the date and time The memory can hold up to 600 entries If the memory is full the oldest entry is deleted and overwritten with the new entry firs...

Страница 153: ...k the corresponding buttons using the mouse The displays on the virtual keypad are the same as those on the alarm panel Note the following If you are logged in as an installer on the web server you op...

Страница 154: ...Wh per year 300 mA 13 8 V Fuse T1A AC input Backup power supply Battery Polymer lithium ion 7 4V Capacity 2500 mAh Minimum running time in emergency power mode 12 hours 24 hours with optional second b...

Страница 155: ...n accordance with EN 50130 4 EMC emissions In accordance with EN 61000 6 3 Electrical safety In accordance with EN 60950 1 Environmental class II EN 50131 1 A1 2009 Security grade 2 EN 50131 1 A1 2009...

Страница 156: ...Wireless accessory module WAM 8 PSTN SMS protocols TAP 8N1 TAP 7E1 UCP 8N1 UCP 7E1 ETSI Protocol 1 Email Up to 8 email addresses Alarm receiving centre protocols ARC Analogue Fast Format Contact ID S...

Страница 157: ...r unable to accommodate parameters 458 Unable to queue message for node 459 Node not allowed reason 500 Syntax error command unrecognized 501 Syntax error in parameters or arguments 502 Command not im...

Страница 158: ...ap eg too many messages exchanged 37648 Internal error eg unexpected failure in lower level module 37776 Unknown identity received eg PSK identity 37904 Public key type mismatch eg asked for RSA key e...

Страница 159: ...the ServerKeyExchange handshake message failed 41616 Processing of the ServerHelloDone handshake message failed 41744 Processing of the ClientKeyExchange handshake message failed 41872 Processing of...

Страница 160: ..._ERROR 15 VOIP_CALL_ICE_CREATE_ERROR 16 VOIP_CALL_ICE_PROCEDURE_ERROR 17 VOIP_CALL_ICE_INVITE_CREATION_ERROR 18 VOIP_CALL_ICE_REINVITE_CREATION_ERROR 19 VOIP_CALL_ICE_REINVITE_SEND_ERROR 20 VOIP_CALL_...

Страница 161: ...ound here http www weltzeit de zeitzonenkarte php All information subject to change Landline notification centre Germany F SMSC operator Protocol Service Centre Tel Materna UCP 8N1 09003 266 9002 Tele...

Страница 162: ...er Wireless mobile phone network SMS service centre Telekom D1 Telekom 491710760000 Vodafone D2 Vodafone 491722270333 alternativ 491722270000 o2 o2 491760000443 BASE E Plus E Plus 491770610000 mobilco...

Страница 163: ...ers that offer their services free of charge GMX web de Yahoo T Online Google Mail Outlook Email notification email setup To send an email to a predefined email address if an event occurs the SMTP log...

Страница 164: ...email address e g yourname arcor de User name email address e g yourname arcor de Password password for email account SSL Disabled GMX Server name mail gmx net Server IP port number 465 Account email...

Страница 165: ...r name smtp gmail com Server IP port number 25 or 587 Account email address e g yourname gmail com User name email address e g yourname gmail com Password password for email account SSL Disabled T Onl...

Страница 166: ...hoo de Server name smtp mail yahoo de Server IP port number 465 Account email address e g yourname yahoo de User name email address e g yourname yahoo de Password password for email account SSL Enable...

Страница 167: ...alarm system 17 Danger detector 15 DEOL 16 Device front 11 Device overview 10 Devices 18 Disarm 19 Display 16 Double end of line 16 Email notification 167 Environmental class 156 Ethernet 35 Event lo...

Страница 168: ...ation 10 Seismic sensor 19 Shock detector 16 Signal transmission 155 Silent alarm 20 Sirens 157 Smoke alarm device 19 SMS service centre 163 Sounder 15 19 Speech dialler 20 Status 20 Status display 37...

Страница 169: ...Index 169...

Страница 170: ...Index 170...

Страница 171: ...ABUS wireless alarm system Secvest Manufacturer ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing Germany...

Отзывы: