Configuration
80
Name/function
Explanation
Exit Mode,
cont.
Disarming the partition
•
The user can use the remote control. The user can also open the door.
The "Final Door" zone at this door starts the entry time. During entry time the
user must disarm the partition using the user code or proximity keyfob at the
alarm panel or control device. (The last method is not compliant with BS8243
clause 6.4.)
As Prtn 1
This option is available for partitions 2, 3 and 4. If this option is selected, the alarm
panel uses the same type as for partition 1.
Settle Time
This option only appears for modes "Final Door Set", "Lock Set" and "Exit Terminate".
Use this option to define a time delay so that detectors can settle before the partition
is internally armed.
This may be necessary if detectors have triggered, send an alarm signal and have
still not been reset.
During this time the alarm panel ignores alarm signals from detectors and sirens
are not triggered.
Enter the time in seconds as a 2-digit number: 01
–
30. The factory default for the
settle time is 15 s.
In this time the wireless PIRs located at the exit which have triggered can settle
and be reset.
Exit Time [s]
This option only appears for modes "Timed Set" and "Silent Set".
Time for the exit delay in seconds.
The exit time can be any value between 10 s and 120 s.
Entry Time [s]
Time for the entry delay in seconds.
The entry time can be any value between 10 s and 120 s.
Alarm Response
Select the response here for when an alarm occurs in this partition.
Internal
•
Alarm panel, indoor siren, info module and control device.
Siren
•
Alarm panel, indoor siren, info module and control device.
•
External Sirens.
Siren + Comms
•
Alarm panel, indoor siren, info module and control device.
•
External Sirens.
•
Communications.
•
A siren delay only goes into effect for alarm response "Siren + Comms".
Содержание SECVEST
Страница 1: ...I n s t a l l e r m a n u a l...
Страница 3: ...Contents 3...
Страница 12: ...Device overview 12 International key assignment...
Страница 14: ...Device overview 14...
Страница 28: ......
Страница 114: ...Configuration 114 ARC Reporting Phone Book Name function Explanation checkbox Tel Recipient Name of the recipient...
Страница 143: ...Configuration 143 Contacts Up to 12 recipients can be defined here to whom messages are sent...
Страница 169: ...Index 169...
Страница 170: ...Index 170...
Страница 171: ...ABUS wireless alarm system Secvest Manufacturer ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing Germany...