Configuration
106
Name/function
Explanation (checkbox)
Auto Rearm
Appears when the following is set:
System->Confirmation->Confirmation Mode->Basic
Select how often the system automatically rearms after the siren time has expired.
Dropdown selection field for:
•
Never
•
The alarm panel never rearms. The alarm panel switches to the alarm status
just one time.
•
1 x, 2 x, 3 x, 4 x, 5 x
•
Always
•
T
he system rearms all closed zones but not the detectors still sending
alarm signals.
•
One of these settings is required in order to comply with EN 50131.
•
If the system is rearmed, an acoustic internal alarm instead of the normal
entry tone is generated by the wireless alarm panel if a user enters through
the entry route.
Silence Alerts
(silent warnings)
This option controls the length of time in which warning tones (a brief "beep" every
few minutes) are sounded.
Dropdown selection field for:
•
User Code
•
Warnings are sounded until a user enters their code to confirm the warning.
•
30 minutes
•
60 minutes
•
120 minutes
•
Warnings are sounded for the set amount of time. The warning tones can be
stopped by entering a user code.
•
No alert tones
•
No acoustic alerts are sounded.
Note
The alarm panel does not display any warnings as long as a partition is still armed.
Abort time
Input field for the alarm abort time in seconds (value between 0 and 120).
The alarm panel always starts this time when an alarm has been triggered. If a user
mutes the alarm during this time, no installer reset is required.
If an alarm occurs and a user disarms the system
within
this time, "Alarm Abort"
outputs are activated and an alarm abort is reported.
Содержание SECVEST
Страница 1: ...I n s t a l l e r m a n u a l...
Страница 3: ...Contents 3...
Страница 12: ...Device overview 12 International key assignment...
Страница 14: ...Device overview 14...
Страница 28: ......
Страница 114: ...Configuration 114 ARC Reporting Phone Book Name function Explanation checkbox Tel Recipient Name of the recipient...
Страница 143: ...Configuration 143 Contacts Up to 12 recipients can be defined here to whom messages are sent...
Страница 169: ...Index 169...
Страница 170: ...Index 170...
Страница 171: ...ABUS wireless alarm system Secvest Manufacturer ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing Germany...