![Abus SECVEST Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/abus/secvest/secvest_installer-manual_3682217047.webp)
Configuration
47
3. This display shows:
•
the zones in which the detector has been
taught in
•
the zone type configured for this detector
•
the partition this detector monitors
•
the additional zone attributes that are available.
4. In addition, "SS:" (signal strength) and the received
signal strength are displayed. To have good
communication, this value should be higher than 3.
Note
If a detector have been successfully taught in,
the alarm panel displays the symbol
next to the
zone number.
For a taught-in zone with a WAM (WAM function 3
sender receiver), "w2" is displayed, for example.
Detector is already used
Note
In rare cases, the message
Detector is already
used
may appear on the display when you are
teaching in a detector, after you have received
confirmation of the teach-in process, because the
detector sends its signal more than once.
In this case the message can be ignored.
This detector may already be taught in in another
zone.
Deleting detectors or de zone information
1. Select the zone in which the detector is registered.
2. Select:
•
Delete Detector ID
when you only wish to
delete the detector
•
Default Zone
when you wish to delete the
detector and the zone information.
3. Confirm the selection with
Next
.
4. Confirm the security prompt with
Yes
to delete the
detector/zone or
Back
if you are not sure.
Delete All (alarm panel only)
1. Select
Delete All
.
2. Confirm the selection with
Next
.
3. Confirm the security prompt with
Yes
to delete the
detector/zone or
Back
if you are not sure.
Содержание SECVEST
Страница 1: ...I n s t a l l e r m a n u a l...
Страница 3: ...Contents 3...
Страница 12: ...Device overview 12 International key assignment...
Страница 14: ...Device overview 14...
Страница 28: ......
Страница 114: ...Configuration 114 ARC Reporting Phone Book Name function Explanation checkbox Tel Recipient Name of the recipient...
Страница 143: ...Configuration 143 Contacts Up to 12 recipients can be defined here to whom messages are sent...
Страница 169: ...Index 169...
Страница 170: ...Index 170...
Страница 171: ...ABUS wireless alarm system Secvest Manufacturer ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing Germany...