Configuration
41
1. Select menu item
Type
Type
Explanation
Not
Used
A zone that is not used because no wireless detector is taught in (no "radio detector learned")
or because its input is not wired to a detector should be configured as zone type "Not Used".
The alarm system does not respond when an event triggers a detector in this zone.
Normal Alarm
If the wireless alarm panel is armed, this zone immediately triggers an alarm if a wireless detector sends
a change to the alarm panel or the status of the alarm zone changes (e.g. alarm contact opens).
Note
Zone type "Normal Alarm" with additional functionality of pry-attempt monitoring for ABUS mechatronics
products such as the FOS 550 E window bar lock, additional door lock or FOS 400 E window lock.
If using a mechatronics product intended for Secvest, configure zone type "Normal Alarm" in the alarm
panel. When the alarm panel is disarmed, these detectors are monitored both for pry attempts and
opening. For this, the window must be closed and the lock secured. Monitoring begins 30 seconds after
locking, as a self-calibration time of 30 seconds is required. If the mechatronic additional lock is
unlocked, monitoring stops. If an attempt is made to open the window without first unlocking the
additional lock, an alarm may be triggered by the movement of the window leaf. Pry-attempt monitoring
can be disabled in the attributes (see "Zone attributes" below).
A passive glass breakage detector can also be connected to some mechatronic products. This detector
sends an alarm when it detects glass breakage, which always leads to an alarm response on the alarm
panel. The alarm panel carries out actions intended for an armed or disarmed status.
Zone Lock
The zone must be locked (closed) in order to arm or internally arm the wireless alarm panel. If the
wireless alarm panel is armed or internally armed, opening this zone does not trigger an alarm.
This zone is used with lock switch contacts.
Note
This zone type was used in the Secvest 2WAY as a zone attribute rather than a zone type.
Exit Norm Alm
A zone configured as "Exit Norm Alm" behaves similarly to a "Normal Alarm" zone. A zone of this
type, however, starts an alarm even when the detector is triggered during the exit time.
Hold Up Alarm
This zone always triggers an alarm, regardless of whether the alarm panel is armed or disarmed.
A hold up alarm can also be transmitted silently (communications). The configuration menu can
only be exited when this zone is closed. Teach in the hold up button (wireless or wall) in this zone.
Fire Alarm
This zone always triggers an alarm, regardless of whether the alarm panel is armed or disarmed.
The alarm is triggered via the sounder in the wireless alarm panel and on the outdoor siren
(external siren) as a pulsed fire alarm sound. Teach in only smoke alarm devices in this zone.
24 Hour Alarm
This zone always triggers an immediate alarm. When the alarm panel is disarmed, the alarm is first
triggered via the integrated sounder in the alarm panel. When the alarm panel is armed, the siren
output is also activated. If a 24 hour zone is disabled, it is only disabled when the alarm panel is
disarmed.
Perimeter
Warning
This zone triggers a pre-alarm when the alarm system is armed or internally armed. The alarm panel
beeps twice every five seconds. "Perimeter Warning" appears on the display every five seconds.
Teach in outdoor motion detectors in this zone, for example.
The wireless outdoor sirens flash and sound for approx. 1 s every five seconds.
The info module beeps every 1 s and the red alarm LED lights up.
The indoor siren sounds every 1 s. This siren must be supplied by a power supply unit for this
purpose, however, and the "alarm only" jumper must not be connected.
(This tone is an "info" tone rather than an "alarm" tone.)
All signals are active for a duration of 30 s.
A "Perimeter Warning" output is activated for 30 s.
When the system is disarmed only the doorbell ("chime") sounds, if configured.
Final Door
When the alarm panel is armed, this zone triggers an alarm once the set delay time (entry delay)
has expired. Use this zone type for the magnetic contact on the entrance door, for example. When
exiting the premises, closing this zone can also be used to end the exit delay. This detector can be
used as a "Normal Alarm" when the system is armed internally.
Содержание SECVEST
Страница 1: ...I n s t a l l e r m a n u a l...
Страница 3: ...Contents 3...
Страница 12: ...Device overview 12 International key assignment...
Страница 14: ...Device overview 14...
Страница 28: ......
Страница 114: ...Configuration 114 ARC Reporting Phone Book Name function Explanation checkbox Tel Recipient Name of the recipient...
Страница 143: ...Configuration 143 Contacts Up to 12 recipients can be defined here to whom messages are sent...
Страница 169: ...Index 169...
Страница 170: ...Index 170...
Страница 171: ...ABUS wireless alarm system Secvest Manufacturer ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing Germany...