Configuration
82
Name/function
Explanation
Pt.Set Entry Route
This option controls how an "Entry Route" zone is handled when the system is
internally armed.
Entry Route
•
Every zone in this partition with type "Entry Route" and the attribute
"Part Set" continues to function as an "Entry Route" zone.
Final Door
•
Every zone in this partition with type "Entry Route" and the attribute
"Part Set" functions as a "Final Door" zone.
Strobe on Set
On
After successfully internally arming the partition, there is
one
visual
acknowledgement on the wireless external siren.
"Strobe" outputs are activated for 10 s after successfully arming the partition.
Off
After successfully internally arming the partition, there is
no
visual
acknowledgement on the wireless external siren.
Strobe on Unset
On
After successfully disarming the partition, there is
one
visual acknowledgement
on the wireless external siren.
"Strobe" outputs are activated for 10 s after successfully arming the partition.
Off
After successfully disarming the partition, there is
no
visual acknowledgement on
the wireless external siren.
Содержание SECVEST
Страница 1: ...I n s t a l l e r m a n u a l...
Страница 3: ...Contents 3...
Страница 12: ...Device overview 12 International key assignment...
Страница 14: ...Device overview 14...
Страница 28: ......
Страница 114: ...Configuration 114 ARC Reporting Phone Book Name function Explanation checkbox Tel Recipient Name of the recipient...
Страница 143: ...Configuration 143 Contacts Up to 12 recipients can be defined here to whom messages are sent...
Страница 169: ...Index 169...
Страница 170: ...Index 170...
Страница 171: ...ABUS wireless alarm system Secvest Manufacturer ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing Germany...