| Error resolution and maintenance –
Identifying errors
26
Error F8
Description
Flash pattern
Per cycle, the red LED flashes once, followed by
the green LED flashing twice.
Cause
Suggested solution
A short circuit has been detected between
the pilot contact CP and the protective earth
PE.
The vehicle's communication interface is
faulty.
The wallbox automatically reinitiates the charging proce-
dure every 60 seconds.
If the error persists, check the charging cable and/or the
charging socket of the wallbox. If you detect any damage,
take the wallbox out of operation and contact the dealer
from whom you have purchased the wallbox.
If no damage is detected when checking the charging cable
and socket, the vehicle must be checked: please contact a
qualified specialist repairer.
Error F9
Description
Flash pattern
Per cycle, the red LED flashes once first,
followed by the green LED flashing three times
and then the blue LED flashing once.
Cause
Suggested solution
The electrical current monitoring module has
detected that the charging current is exceeding
the preset maximum current.
The wallbox automatically reinitiates the charging proce-
dure every 60 seconds. If the error persists, the wallbox
and/or the vehicle must be checked: please contact a quali-
fied specialist electrical contractor or a specialist repairer.
Error F10
Description
Flash pattern
Per cycle, the red flashes once first,
followed by the green LED flashing twice
and then the green and blue LED flashing twice.
Cause
Suggested solution
The temperature monitoring device has detect-
ed a temperature above 80° Celsius inside the
housing.
The temperature monitor interrupts the charging procedure.
After 10 minutes, the charging procedure is automatically
re-initiated. If the temperature inside the housing remains
at between 60° and 80° Celsius, error code
F17
(see below)
is shown and the charging current is limited to 6 A.
The charging procedure is reinitiated immediately as soon
as the temperature inside the housing falls to below 60°
Celsius.
If the error repeats or persists, the wallbox must be cooled
and/or shaded more effectively at the installation site.
Should the error persist, please take the wallbox out of
operation (see page 29) and contact a qualified specialist
electrical contractor to resolve the error.
Содержание WALLBOX eMH2 EN