| Configuring the Wallbox eMH2 –
Stand-alone operation of a Slave wallbox
18
3
Loosen the screw of the internal electronic com-
ponents cover using the screwdriver (Torx) and put
it aside.
y
Keep the screw in a safe place.
4
Connect the computer to the wallbox.
y
Connection via USB interface:
Using the USB extension cable, connect the
USB port in the upper section of the housing
base with a free USB port on your computer.
y
Connection via LOMK218:
Connect the RS485-RJ12 adapter with the
spring terminals for the CONTROL bus of the
wallbox.
»
The CONTROL bus is always assigned
to the left three spring terminals of each
terminal block.
»
Using the USB-RS485 cable, connect the
USB-RS485 adapter to your computer.
A M B
CONTROL
A M B
METER
A M B
CONTROL
A M B
METER
You can find further information in the manual for the
LOMK218
cable set, which you can download
Service > All downloads > Operation manuals > Accessories
section.
5
Switch the Slave wallbox on.
6
Open the
Configuration Software
application
on your computer.
y
The application opens.
Configuration
Software
7
From the
Select COM Port
drop-down list,
select the highest COM port available.
Содержание WALLBOX eMH2 EN