3 Product Description
Hazards
caused by improper use
If improperly used, the device can present risks to persons, animals, and material
property.
WARNING
•
Use the device according to its designated use only.
•
Do not convert and modify the device to enhance its performance without
authorization.
•
Only qualified personnel are permitted to perform work on the device or
system.
3 Product Description
3.1 Technical Data
Ambient temperature of welding
-
1
0
°C to + 40
°C
Relative humidity
Up
to 90
% at 20
°C
Tab. 1
Ambient conditions during operation
Storage in a closed enviornment, ambient temperature
Ambient Temperature for shipment
Relative Humidity
Up
to 90% at 20°C
Tab. 2
Ambient conditions for transport and storage
-
1
0
°C to + 40
°C
-
25
°C to +
55
°C
Type of voltage
DC
Polarity of the electrodes
Usually positive
Wire types
C
ommercially available round wires
Type of use
A
utomatic
Voltage rating
Peak value of 141 V
Protection type of the machine-side connections
IP3X (EN 60 529)
Shielding gas (
EN ISO 14175)
CO
2
and mixed gas M21
Tab.
3
Generial torch data according to EN 60 974-7
EN
6
xFUME
®
ABIROB
®
A