10 Troubleshooting
5
Place the retaining sleeve
(1)
inverted by 180° onto the new spiral liner
(6)
(side without
thread).
6
Cut off the overlapping spiral liner
(6)
flush with the retaining sleeve
(1)
.
7
Screw the collet
(5)
onto the spiral liner
(6)
as far as it will go.
Use the sight bore on the collet
(5)
to check the position of the wire guide.
8
Slide the collet
(5)
and spiral liner
(6)
into the central connector
(2)
as far as they will go.
9
Screw the
threaded side of the retaining sleeve
(1)
into the central connector
(2)
and
tighten.
10
Use the nut
(3)
to secure the cable assembly
(4)
to the central connector
(2)
.
9.3
Cleaning the torch neck
To increase the system availability of the welding robot,
ABICOR
BINZEL
offers automated torch cleaning.
1
Remove the gas nozzle.
2
Remove the weld spatter and spray with
ABICOR
BINZEL
anti-spatter fluid.
3
Check the wear parts for visible damage and replace them if necessary.
4
Replace the equipment kit when worn or soiled.
5
Clean the separating point and O-rings with silicone-free seal grease.
6
Check the TCP after each use or after a collision in the WH alignment jig.
10
Troubleshooting
Please observe the attached ‘Warranty’ document. In the event of any doubts and/or problems, please contact
your retailer or the manufacturer.
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair
work and modifications to the product may lead to serious injuries and damage to the device. The product
warranty will be rendered invalid if work is carried out on the product by unauthorized persons.
•
Only qualified personnel are permitted to perform work on the device or system.
NOTICE
• Consult the documentation for the welding components.
EN