background image

2 Safety

Note that if additional hoses or hoses from other manufactures are used,

 

pressure loss in the fume

extraction torch can result.

Note that the applied vacuum depends on the geographic altitude of the

 

operation site.

Observe the warning signals and indicators on the fume extraction system.

 Warning

 signals and indicators

can imply a saturated filter or a problem

 

with/damage to the fume torch.

Replace the extraction-specific wear parts at regular intervals. The

 

replacement interval required depends

on the application conditions.

Open the 

handle 

regulator for only a moment and close is quickly after opening it.

 

The air regular must be

closed

 

to ensure efficient capture of fumes.

Observe the instructions on the adapter label for connecting components.

When used with welding fume extraction systems of the 

xFUME® 

series.

The degree to which welding fumes are captured during torch

 integrated

 extraction depends on many

factors, such as the position of

 

the suction nozzle, the welding geometry, and the rate of smoke

 

emission

during the welding process. Under optimal conditions, over

 

95% of the welding fumes can be captured in

accordance with ISO

 

21904-3.

2.

6

 

Emergency Information

In case of emergency, immediately disconnect the following supplies

:

Electrical power

 

supply

Compressed air

 

supply

Gas supply

Further measures can be found in the operating instructions for the power source or the documentation for other 
peripheral devices.

EN 

5

 

xFUME

®

ABIROB

®

A

F500

Содержание xFUME ABIROB AF500

Страница 1: ...www binzel abicor com xFUME ABIROB AF500 Welding Torch Systems EN Operating Instructions...

Страница 2: ...11 6 EN 12 6 1 6 2 Identification Marking Safety Designated use Obligations of the operator Personal protective equipment PPE Classification of the warnings Safety Instructions Emergency information P...

Страница 3: ...fety and accident prevention those who have been instructed on how to handle the device those who have read and understood these operating instructions those who have read and understood the chapter e...

Страница 4: ...ht or minor injuries NOTICE Describes the risk of impairing work results or the risk that the work may result in material damage to the equipment 2 4 Classifications of Warnings 2 5 Safety Instruction...

Страница 5: ...ar must be closed to ensure efficient capture of fumes Observe the instructions on the adapter label for connecting components When used with welding fume extraction systems of the xFUME series The de...

Страница 6: ...C to 40 C Relative humidity Up to 90 at 20 C Tab 1 Ambient conditions during operation Storage in a closed enviornment ambient temperature Ambient Temperature for shipment Relative H umidity Up to 90...

Страница 7: ...0974 7 1 for pulse arcs the load data are reduced by up to 35 Fig 1 Torch neck dimensions DESCRIPTION SWANNECK TCP X Y Solid Torch Mount 180 Degree 14 2 360mm Solid Torch Mount 22 Degree 14 2 360mm 5...

Страница 8: ...nt DC Duty cycle MIG Metal inert Gas MAG Metal active Gas MAC Maximum allowable concentration of harmful substances at the workplace Voltage rating Classification of the insulation resistance voltage...

Страница 9: ...out in succession 4 Scope of Delivery Torch sided cable support with integrated switch housing cover Machine side cable support with central connector Operating instructions The xFUME ABIROB AF500 re...

Страница 10: ...inspection In case of complaints If the delivery has been damaged during transportation contact the last carrier immediately Retain the packaging for potential inspection by the carrier Packaging for...

Страница 11: ...rovides the welding torch with all the components required for welding e g the welding current shielding gas and air A fume hose is included but must be connected to an extractor for at source fume ex...

Страница 12: ...able tip adapter 4 onto the torch neck 7 using the wrench 9 2 Screw the contact tip 2 into the tip adapter 4 and tighten using the wrench 9 3 Grease the torch neck 0 rings and insert the torch neck 7...

Страница 13: ...Maintenance and cleaning on page EN 18 Spiral liners for steel and stainless steels PA liners for aluminum copper nickel and stainless steels 6 Putting into operation EN 13 1 Clamp 2 Handle 3 Control...

Страница 14: ...the wire 1 Insert the wire in the wire feeder as specified by the manufacturer 2 Press the zero current wire feed button on the wire feeder NOTICE The type and amount of shielding gas used depend on...

Страница 15: ...of the welding area DANGER Risk of burns During welding activities sparks glowing workpieces or hot slag can produce flames Check the work area for flashpoints Provide appropriate fire extinguishing...

Страница 16: ...ved DANGER Risk of injury due to unexpected start The following instructions must be adhered to during all maintenance servicing assembly disassembly and repair work Switch off the power source Close...

Страница 17: ...2 Disconnect the central connector 2 from the feed unit 3 Screw on the retaining sleeve 1 4 Replace the old spiral liner 6 with a new one and insert the stripped side into the central connector 2 WAR...

Страница 18: ...the weld spatter and spray with ABICOR BINZEL anti spatter fluid 3 Check the wear parts for visible damage and replace them if necessary 4 Replace the equipment kit when worn or soiled 5 Clean the sep...

Страница 19: ...ip Wrong contact pressure set on the wire feeder Correct as specified by the manufacturer Arc between the gas nozzle and the workpiece Spatter bridge between the contact tip and the gas nozzle Clean a...

Страница 20: ...intenance servicing assembly disassembly and repair work Switch off the power source Close off the compressed air supply Close off the gas supply Switch off the entire welding system Disconnect all el...

Страница 21: ...h the information provided by the consumables manufacturer 12 3 Packaging ABICOR BINZEL has reduced the transport packaging to the necessary minimum The ability to recycle packaging materials is alway...

Отзывы: