BAL.0193.0 • 2018-07-31
EN - 13
MT/AUT/AUT RAB
6 Commissioning
6.2.2 PA liner
PA liners = for aluminium, copper, nickel and stainless steels
1
Sharpen the beginning of the PA liner
to approx. 40° with the
ABICOR BINZEL
sharpener
.
2
Slide PA liner
through the wire conduit
into the contact tip until a noticeable
resistance is felt.
3
Slide clamp nipple
, O-ring
on the PA liner
under tension.
4
that is too long in front of the wire feed rollers.
5
Cut the PA liner
at the mark with the
ABICOR BINZEL
cutter
6
Sharpen the cutting point.
NOTICE
• New, as yet unused PA liners have to be abridged to the actual length of the cable
assembly.
• For PA liners with an outer diameter of 4.00 mm, the capillary tube in the distance
adaptor must be replaced with a guide tube.
• We recommend that you sharpen the PA liner to an angle of 40° before assembly using
the
ABICOR BINZEL
sharpener.
1
Wire conduit
2
Central plug
3
Nut
4
Wire feed unit
5
ABICOR BINZEL
Cutter
6
Guide tube
7
O-ring
8
Clamp nipple
9
PA liner
10 ABICOR BINZEL
Sharpener
Fig. 4
Shortening the PA liner
40 °
1
2
4
5
9
8
6
10
3
7