EN - 6
BAL.0193.0 • 2018-07-31
3 Product description
MT/AUT/AUT RAB
Type
Type of
cooling
Load
Duty
cycle
Wire-
Gas flow
Cooling data
dual
circiut
supply
temp
flow
flow pressure
CO
2
M21
max.
min.
min.
max.
MT
A
A
%
mm
l/min
°C
l/min
bar
bar
555 W
liquid
575
525
100
1,0 - 1,6
10 - 20
40
1,15
2,5
3,5
555 DW
liquid
550
500
100
1,0 - 1,6
10 - 20
40
1,15
2,5
3,5
605 W
liquid
625
575
100
1,0 - 1,6
10 - 20
40
1,15
2,5
3,5
605 DW
liquid
600
550
100
1,0 - 1,6
10 - 20
40
1,15
2,5
3,5
Tab. 4
Product specific torch data (EN 60 974-7) ABIMIG
®
MT
Type
Type of
cooling
Load
ED
Wire
Gas flow
Cooling data
Supply
temp.
flow
flow pressure
CO
2
M21
max.
min.
min.
max.
AUT
A
A
%
mm
l/min
°C
l/min
bar
bar
15 AK
air
180
150
60
0.6 - 1.0
10 - 18
25 AK
air
230
200
60
0.8 - 1.2
10 - 18
24 KD
air
250
220
35
0.8 - 1.2
10 - 18
26 KD
air
230
200
35
0.8 - 1.2
10 - 18
36 KD
air
300
270
60
0.8 - 1.2
10 - 20
40 KD
air
350
320
35
1.0 - 2.4
10 - 20
240 D
liquid
300
270
100 0.8 - 1.2
10 - 20
40
1
2.5
3.5
401 D
liquid
400
350
100 0.8 - 1.6
10 - 20
40
1
2.5
3.5
401
liquid
450
400
100 0.8 - 1.6
10 - 20
40
1
2.5
3.5
501 D
liquid
500
450
100 1.0 - 1.6
10 - 20
40
1
2.5
3.5
501
liquid
550
500
100 1.0 - 1.6
10 - 20
40
1
2.5
3.5
602
liquid
600
550
100 1.0 - 1.6
10 - 20
40
1.3
2.5
3.5
Tab. 5
Product specific torch data (EN 60 974-7) AUT