EN - 12
7 Operation
ABIROB
®
A
1
Connect shielding gas cylinder to the wire feeding system.
2
Set the gas quantity on the pressure reducer of the shielding gas cylinder.
6.6 Introducing the wire
1
Insert the wire in the wire feed unit as specified by the manufacturer.
2
Press the "Current-less wire feed" push-button at the wire feed unit.
7 Operation
NOTE
• Make all shielding gas connections gas-tight.
NOTE
• Each time you change the wire, make sure that the beginning of the wire
is burr-free.
DANGER
Shortness of breath and poisoning caused by inhaling
phosgene gas
During the welding of work-pieces that have been degreased with chlorine-
containing solvents phosgene gas is formed.
• Do not inhale fumes and vapors.
• Ensure sufficient supply of fresh air.
• Rinse work-pieces with clear water prior to welding.
• Do not place degreasing baths containing chlorine in the vicinity of the
welding area.
DANGER
Risk of burns
During welding work spraying sparks, glowing work-pieces or hot slag can
produce flames.
• Check work area for seats of fire.
• Make suitable fire extinguishing materials available at the workplace.
• Allow work-pieces to cool down after welding.
• Prior to performing welding work, fasten the ground clamp properly to
the work-piece or the welding table.