EN - 4
2 Product Description
ABIROB
®
A
2.2 Use contrary to the designated use
Any use other than that described under "Designated Use" is considered
contrary to the designated use. Unauthorized conversions or power increase
modifications are not allowed. The warranty does not cover wearing parts and
damage due to overloading or improper use.
2.3 Technical Data
Ambient temperature of welding
- 10 °C to + 40 °C
Transport and storage
- 25 °C to + 55 °C
Relative humidity
up to 90 % at 20 °C
Tab. 2
Temperature
Type of voltage
DC
Polarity of the electrodes
Usually positive
Wire types
commercially available round wires
Type of use
Hand-held
Voltage rating
Peak value of 141 V
Protection type of the machine side connections
IP3X (EN 60 529)
Shielding gas (DIN EN 439)
CO
2
and mixed gas M21
Tab. 3
General torch data according to EN 60 974-7
Type
Type of
cooling
Load
1
ED
Wire ø
Gas flow
Weight
CO
2
M21
ABIROB
®
A
(A)
(A)
(%)
(mm)
(l/min)
A360
air
360
290
100
0.8 - 1.2
10 - 20
800
A500
air
500
40
100
0.8 - 1.6
10 - 30
900
Tab. 4
Product specific torch data as laid out in EN 60974-7
1For pulse arcs, the load data are reduced by up to 35%.