38
ProKiln GAC400
PROBE GAS SAMPLING SYSTEM | OI/GAC400-EN REV. A
… 5 Transport and storage
… Transport
Environmental conditions
Observe the following physical limits when transporting the
modules:
Module
Environmental conditions for transport
Retractor unit
including the
probe
Ambient temperature:
+5 °C to +45 °C, after completely
draining all water and drying parts in contact with cooling
water or condensation: -20 °C to +45 °C
Air humidity
: Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted
Cooling unit
Ambient temperature:
+5 °C to +55 °C, after completely
draining all water and drying parts in contact with cooling
water or condensation: -20 °C to +55 °C
Air humidity
: Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted
Water unit
Ambient temperature:
+5 °C to +45 °C, after completely
draining all water and drying parts in contact with cooling
water or condensation: -20 °C to +45 °C
Air humidity
: Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted
Control cabinet
Ambient temperature:
-20 °C to +45 °C
Air humidity:
Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted
Flange shutter
Ambient temperature:
-20 °C to +55 °C
Air humidity:
Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted
Unpacking the system
Instructions
Perform the following steps to unpack the system:
1. Remove outer packaging:
• Transport crate
• Tensioning straps
• Cardboard, films, and wooden parts
2. Undo fasteners holding the system parts on the pallet.
Before doing it, take care that the equipment stands in a
stable way and cannot fall down.
3. Lift system parts off the pallet with a crane, fork-lift truck or
hand lift (recommended at least 2 persons for hand-lifting).
Note: The retractor must not be transported with a fork-lift
truck.
4. Dispose of packaging material in accordance with the
national regulations.
5. Transport system parts to the place of installation
Scope of delivery
Scope of delivery (standard)
The following components are delivered as standard:
• Probe retractor including probe
• Control cabinet
• Water panel
• Cooling panel with 1” hoses for connection to water panel
• Complete electrical documentation in electronic format
• System operating instructions in electronic format
• Also supplies (filter tools, set of O-rings, leakages test plug)
• Electrical documentation and operating instructions in print-
out version placed in door of control cabinet
Scope of delivery (optional)
The following optional components may be included in the scope
of delivery:
• Automatic flange shutter
• Water tank heater for ambient temperature below +5C°
• Double probe configuration
• Heated sample shut-off valve (attached to retractor frame)
• Air tank 270 L CE approved