LEANtouch (monochrome),
SMARTtouch (monochrome, colour)
Type: 6x36/30M(-500), 6x36/100x(-500), 6x36/100CB
Functional description: Presence
simulation
Functional description: Presence
simulation
Function
Application
Simulation
Inactive
Active
Communication objects
No.
Type
Object name
Function
0
1 bit
Activation
Receive
1
1 bit
Simulation 1
Send/Receive
2
1 bit
Simulation 2
Send/Receive
3
1 bit
Simulation 3
Send/Receive
4
1 bit
Simulation 4
Send/Receive
5
1 bit
Simulation 5
Send/Receive
6
1 bit
Simulation 6
Send/Receive
7
1 bit
Simulation 7
Send/Receive
8
1 bit
Simulation 8
Send/Receive
9
1 bit
Simulation 9
Send/Receive
10
1 bit
Simulation 10
Send/Receive
– Waiting time up to the activation
30s / 40s / 50s / 1min / 1.1min /
1.2min / 1.5 min / 2 min
Parameters: Presence simulation
The default setting of the values
is printed in bold type.
The panel has an integrated
presence simulation function. This
means that the panel can send out
telegrams fully independently and
conveys the impression that the
house is occupied.
If the presence simulation function is
activated, the panel software displays
10 x 1-bit communication objects
“Simulation 1” to “Simulation 10” for
controlling switch and/or shutter
actuators and a 1-bit communication
object “Activation” for the activation or
deactivation of the presence
simulation.
The presence simulation is activated
with an ON telegram at the “Activation”
object. An OFF telegram deactivates it
again.
If the presence simulation is not
active (OFF telegram has been
received at the activation object), it
portrays “normal” telegram traffic. The
panel learns the habits of the
occupants of the house. The panel
has a memory which records
telegrams for seven days. On the
eighth day, the memory location of the
first of the seven days is overwritten.
If the panel only had three days to
carry out a recording, only these three
days are repeated when the function
is activated.
The panel ignores cyclical
transmitters during the recording.
This means it only records an actual
change.
Once an ON telegram has been
received at the “Activation” object, the
panel first waits until the “Waiting time
up to the activation” has elapsed. Only
then does the simulation start. The
delay can be set between 30 s and
2 min.
The activated presence simulation
sends the information that has been
recorded over several days on a 1:1
basis.
It is a good idea to integrate functions
in the presence simulation which are
not linked with a holiday function of a
time channel. This could be e.g. the
lounge light, the kitchen light and
above all the hallway light.