Note/Illustration
Action
Note
The track motion does not need to be calibrated
during restart. The resolvers only need to be cal-
ibrated when commissioning the system.
2
Using the FlexPendant, jog the carriage close to
the calibration gauge position.
3
xx2200001160
Jog the carriage to move it until the calibration
holes line up.
4
xx2200001161
Insert the calibration pin (3HAW107700354).
A dowel pin diameter 8 mm can also be used.
5
Tap
ABB
on the top left of the FlexPendant
6
Tap
Calibration
.
7
Select the desired mechanical unit.
8
Tap
Fine calibration
.
9
Select the desired axis.
10
Tap
Calibrate
.
11
358
Product manual - IRT 710
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
6 Calibration
6.5 Pin calibration
Continued
Содержание IRT 710
Страница 1: ...ROBOTICS Product manual IRT 710 ...
Страница 2: ...Trace back information Workspace Systems version a40 Checked in 2023 10 18 Skribenta version 5 5 019 ...
Страница 14: ...This page is intentionally left blank ...
Страница 58: ...This page is intentionally left blank ...
Страница 84: ...This page is intentionally left blank ...
Страница 360: ...This page is intentionally left blank ...
Страница 364: ...This page is intentionally left blank ...
Страница 378: ...This page is intentionally left blank ...
Страница 380: ...This page is intentionally left blank ...
Страница 383: ......