Preparation prior to calibration
The calibration procedure is described in the FlexPendant while conducting it.
Note
Action
DANGER
While conducting the calibration, the track needs
to be connected to power.
Make sure that the track's working area is empty,
as the robot can make unpredictable movements.
1
Use a clean cloth.
Wipe the calibration tool clean.
Note
The calibration method is exact. Dust, dirt or color
flakes will affect the calibration value.
2
Starting the calibration procedure
Use this procedure to start the Axis Calibration routine on the FlexPendant.
Note
Action
Tap the calibration icon and enter the calibration
main page.
1
All mechanical units connected to the system are
shown with their calibration status.
2
Tap the mechanical unit in question.
The FlexPendant will give all inform-
ation needed to proceed with Axis
Calibration.
The calibration method used at ABB factory for
each axis is shown, as well as calibration method
used for the robot during last field calibration.
3
Valid for RobotWare 6
4
Tap
Call Calibration Method
. The software will
automatically call for the procedure for the valid
calibration method. If not, tap
Call Routine
and
then tap
Axis calibration
.
A brief overview of the sequence
that will be run on the FlexPendant
is given in
tion procedure on the FlexPendant
on page 351
Follow the instructions given on the FlexPendant.
5
Restarting an interrupted calibration procedure
If the Axis Calibration procedure is interrupted before the calibration is finished,
the RobotWare program needs to be started again. Use this procedure to take
required action.
Action
Situation
Press and hold the three-position enabling
device and press
Play
.
The three-position enabling device on the
FlexPendant has been released during robot
movement.
Continues on next page
Product manual - IRT 710
353
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
6 Calibration
6.4.4 Axis Calibration - Running the calibration procedure
Continued
Содержание IRT 710
Страница 1: ...ROBOTICS Product manual IRT 710 ...
Страница 2: ...Trace back information Workspace Systems version a40 Checked in 2023 10 18 Skribenta version 5 5 019 ...
Страница 14: ...This page is intentionally left blank ...
Страница 58: ...This page is intentionally left blank ...
Страница 84: ...This page is intentionally left blank ...
Страница 360: ...This page is intentionally left blank ...
Страница 364: ...This page is intentionally left blank ...
Страница 378: ...This page is intentionally left blank ...
Страница 380: ...This page is intentionally left blank ...
Страница 383: ......