4.3.4 Inspecting the levelling screw
Location of levelling screw
The leveling screw are located as shown in figure.
xx2200000628
Required equipment
Note
Article number
Equipment, etc.
-
Visual inspection
Inspecting the levelling screw
Use this procedure to inspect the leveling screw.
Note
Action
Tighten torque:
Check the M16 chemical anchor bolts for
any loosen.
•
If any loosen is detected, retighten
it.
1
80 Nm (Chemical anchor bolts directly
connected to the foundation)
308 Nm (M16 bolts connected to the floor
plate)
Continues on next page
190
Product manual - IRT 710
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
4 Maintenance
4.3.4 Inspecting the levelling screw
Содержание IRT 710
Страница 1: ...ROBOTICS Product manual IRT 710 ...
Страница 2: ...Trace back information Workspace Systems version a40 Checked in 2023 10 18 Skribenta version 5 5 019 ...
Страница 14: ...This page is intentionally left blank ...
Страница 58: ...This page is intentionally left blank ...
Страница 84: ...This page is intentionally left blank ...
Страница 360: ...This page is intentionally left blank ...
Страница 364: ...This page is intentionally left blank ...
Страница 378: ...This page is intentionally left blank ...
Страница 380: ...This page is intentionally left blank ...