xx2200000842
Safety door with interlock device for mechanical safety fence
The calculation formula corresponding to the minimum safety distance is:
S = K*T+C
K = 2000 mm/s (Approaching speed of the walking human)
T = The maximum time for the machine to stop + Interlock response time
C = 850 mm (Traverse distance)
Note
If the recalculated value ≤ 500mm, then S should be set as 500 mm.
Note
The interlock device should follow the dual channel requirements.
Continues on next page
Product manual - IRT 710
19
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
1 Safety
1.1.3 Safeguarded space
Continued
Содержание IRT 710
Страница 1: ...ROBOTICS Product manual IRT 710 ...
Страница 2: ...Trace back information Workspace Systems version a40 Checked in 2023 10 18 Skribenta version 5 5 019 ...
Страница 14: ...This page is intentionally left blank ...
Страница 58: ...This page is intentionally left blank ...
Страница 84: ...This page is intentionally left blank ...
Страница 360: ...This page is intentionally left blank ...
Страница 364: ...This page is intentionally left blank ...
Страница 378: ...This page is intentionally left blank ...
Страница 380: ...This page is intentionally left blank ...
Страница 383: ......