However, SafeMove may generate other warning messages anytime during the
Axis Calibration routine. When a warning message is displayed, tap
Acknowledge
to confirm the unsynchronized state and continue Axis Calibration procedure.
CAUTION
SafeMove must be synchronized after the calibration is completed.
After calibration
Note
Action
xx1600002102
Check the o-ring on the fixed calibration pin.
Replace if damaged or missing.
1
Reinstall the protective cover on the fixed calibra-
tion pin on each axis, directly after the axis has
been calibrated.
Replace the cover with new spare part, if missing
or damaged.
2
Protection cover and plug set:
3HAC056806-001.
xx1500000952
Reinstall the protective plug and sealing in the
bushing on each axis, directly after the axis has
been calibrated. Ensure that the sealing is not
damaged.
Replace the plug and the sealing with new spare
part, if missing or damaged.
3
Protection cover and plug set:
3HAC056806-001.
See
Calibrating with Wrist Optimiz-
If the standard calibration data for axes 4, 5 or 6
should be updated with wrist optimization, run the
calibration routine
Wrist Optimization
.
4
712
Product manual - IRB 8700
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.
5 Calibration
5.4.4 Axis Calibration - Running the calibration procedure
Continued
Содержание IRB 8700
Страница 1: ...ROBOTICS Product manual IRB 8700 ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 96: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 718: ...This page is intentionally left blank ...
Страница 724: ...This page is intentionally left blank ...
Страница 742: ...This page is intentionally left blank ...
Страница 748: ......
Страница 749: ......