Note
Action
Screw M16x80 (Fully threaded, 2 pcs, 2
pcs)
xx1500002309
Unload the pressure of the balancing
device by inserting the screws.
1
Attach the screws until the screws
reaches the piston.
xx1900001209
2
Then, alternately little by little, attach
the screws at least another
five
milli-
meters. The pressure is now un-
loaded.
xx1900001210
5
In a procedure where both balancing
devices shall be removed, unload the
pressure of the other in the same way.
6
Removing both balancing devices
Use this procedure to remove both balancing devices.
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Mobile platform ladder
xx1500001985
Use a mobile platform ladder to reach the
upper end of the balancing device.
DANGER
Do not use the robot as a ladder.
2
Continues on next page
Product manual - IRB 8700
247
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the upper arm
Continued
Содержание IRB 8700
Страница 1: ...ROBOTICS Product manual IRB 8700 ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 96: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 718: ...This page is intentionally left blank ...
Страница 724: ...This page is intentionally left blank ...
Страница 742: ...This page is intentionally left blank ...
Страница 748: ......
Страница 749: ......