Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
7
Remove any equipment that obstructs ac-
cess to the motor.
8
Disconnecting the axis-2 or axis-3 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1200001135
Unscrew the attachment screws and
washers and remove the motor cover.
2
xx1200001070
Make sure the o-ring is present.
3
Continues on next page
Product manual - IRB 8700
477
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.
4 Repair
4.7.2 Replacing the axis-2 and axis-3 motors
Continued