Note
Action
Note
Do not refit anything else of the axis-6 mo-
tor cables at this point. The remaining refit-
ting must wait until the axis-5 has been
moved into +90° position.
Axis-5 must be in +90° position when the
carrier and cable bracket are refitted. If not,
the spiral of the cable harness will be in the
wrong position and it will be damaged when
axis-5 is moving.
3
Robot position when refitting the axis-6 motor cables
Note
Action
Turn on the power, use caution and jog
axis-5 slowly to +90° position.
CAUTION
Make sure not to touch or damage any of
the axis-6 motor cables.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
2
Disconnect the axis-6 motor cables.
3
Connecting the axis-6 motor cables - Step 2
Note
Action
Make sure that the axis 5 now is in +90°
position before continuing.
1
If not, the cable spiral will be attached in
the wrong position and the result will be
damage to the cable harness.
CAUTION
Make sure that the cable spiral is not twis-
ted an extra revolution. The result will be
damage to the cable harness.
Continues on next page
Product manual - IRB 8700
281
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the upper arm
Continued
Содержание IRB 8700
Страница 1: ...ROBOTICS Product manual IRB 8700 ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 96: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 718: ...This page is intentionally left blank ...
Страница 724: ...This page is intentionally left blank ...
Страница 742: ...This page is intentionally left blank ...
Страница 748: ......
Страница 749: ......