Removing the motor
Use these procedures to remove the motor.
Preparations before removing the axis-5 motor
Note
Action
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
1
Jog the robot to the specified position:
•
Axis 1: no significance, as long as
the robot is secured to the founda-
tion
•
Axis 2: comfortable working position
•
Axis 3: comfortable working position
•
Axis 4: +90°
•
Axis 5: no significance
•
Axis 6: no significance.
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
3
Retrieving access to the wrist cabling
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1500003100
Remove the wrist cover.
Note
Do not damage the sealing. Replace if
damaged.
Note
The position of axis-4 depends on the on-
going procedure.
2
xx1500002330
Continues on next page
Product manual - IRB 8700
501
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.
4 Repair
4.7.4 Replacing the axis-5 motor
Continued
Содержание IRB 8700
Страница 1: ...ROBOTICS Product manual IRB 8700 ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 96: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 718: ...This page is intentionally left blank ...
Страница 724: ...This page is intentionally left blank ...
Страница 742: ...This page is intentionally left blank ...
Страница 748: ......
Страница 749: ......