Information
Action
Tightening torque: 2 Nm.
xx0900000848
Refit the
lower arm covers
.
21
Clean Room robots: seal and paint the joints
that have been opened. See
Note
After all repair work, wipe the robot free
from particles with spirit on a lint free cloth.
22
See chapter:
•
Recalibrate the robot.
23
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
- First test run may cause injury or damage!
on page 47
.
24
Product manual - IRB 120
201
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
4 Repair
4.7.2 Replacing axis-2 motor with gearbox