Value
Parameter
+55° C
Maximum ambient temperature
+70° C
Maximum ambient temperature (less than 24 hrs)
95% at constant temperature
(gaseous only)
Maximum ambient humidity
Operating conditions, robot
The table shows the allowed operating conditions for the robot:
Value
Parameter
+5ºC
i
Minimum ambient temperature
+45ºC
Maximum ambient temperature
+35ºC
ii
Maximum ambient temperature for robots with food grade
lubrication
Max 95% at constant temperature
Maximum ambient humidity
i
At low environmental temperature < 10ºC is, as with any other machine, a warm-up phase
recommended to be run with the robot. Otherwise there is a risk that the robot stops or run with
lower performance due to temperature dependent oil and grease viscosity.
ii
For robots with food grade lubrication, if environment temperature > 35ºC, contact ABB for further
information.
Protection classes, robot
The table shows the available protection types of the robot, with the corresponding
protection class.
Protection class
Protection type
IP 30
Manipulator, protection type Standard
IP 30
Manipulator, protection type Clean Room
Product manual - IRB 120
59
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
2 Installation and commissioning
2.2.1 Pre-installation procedure
Continued
Содержание IRB 120
Страница 1: ...ROBOTICS Product manual IRB 120 ...
Страница 2: ...Trace back information Workspace R17 2 version a11 Checked in 2017 09 20 Skribenta version 5 1 011 ...
Страница 8: ...This page is intentionally left blank ...
Страница 90: ...This page is intentionally left blank ...
Страница 114: ...This page is intentionally left blank ...
Страница 224: ...This page is intentionally left blank ...
Страница 250: ...This page is intentionally left blank ...
Страница 254: ...This page is intentionally left blank ...
Страница 264: ...This page is intentionally left blank ...
Страница 270: ......
Страница 271: ......