Information
Action
Place the cable harness inside the cable
holder.
10
xx1500000002
Loosen the
cable bracket
next to motor axis
1.
11
Reconnect connectors:
•
R2.MP1
•
R2.ME1.
12
Secure the
motor cables
to the cable
bracket with cable ties.
13
M3x8 (2 pcs)
Fasten
cable bracket
.
14
Är detta earth connection? Om inte, vad
är det för kabel?
Refit the
PE cable
.
15
Attachment screw (4 pcs) M3x8
Refit the
EIB board
.
Note
Use ESD protective equipment.
16
Connect
board
.
•
R1.ME4-6 (J4)
•
R1.ME1-3 (J3)
•
R2.EIB.
17
Connect
battery cables
.
18
Attachment screw (4 pcs) M3x8
Refit the
battery plate
.
19
Attachment screw (4 pcs) M3x8
Refit the
EIB plate
.
CAUTION
Cables are sensitive equipment. Use caution
when handling cables.
20
Continues on next page
Product manual - IRB 120
137
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
4 Repair
4.3.2 Refitting the cable harness
Continued
Содержание IRB 120
Страница 1: ...ROBOTICS Product manual IRB 120 ...
Страница 2: ...Trace back information Workspace R17 2 version a11 Checked in 2017 09 20 Skribenta version 5 1 011 ...
Страница 8: ...This page is intentionally left blank ...
Страница 90: ...This page is intentionally left blank ...
Страница 114: ...This page is intentionally left blank ...
Страница 224: ...This page is intentionally left blank ...
Страница 250: ...This page is intentionally left blank ...
Страница 254: ...This page is intentionally left blank ...
Страница 264: ...This page is intentionally left blank ...
Страница 270: ......
Страница 271: ......